Télécharger Imprimer la page

fadini Elpro 37 Mode D'emploi page 10

Programmateur electronique monophasé - triphasé
Masquer les pouces Voir aussi pour Elpro 37:

Publicité

Les langues disponibles

Les langues disponibles

Elpro 37
GB
ATTENTION:
!
before starting the electrical connections, check the voltage (230 V or 400 V) selector switch to be set correctly.
In cases a motor with mechanical brake is used or a control board ELPRO 10 is to be changed, the dip-switch - A N° 12 has to be in OFF.
SAFETY EDGE
in CLOSING
Power supply
24 V - 50 mA max
_
+
26
27
JB
28
CARD
CONNECTOR FOR
TRAFFIC LIGHTS
(Item 7282L)
PLUG-IN
RADIO
CARD
CONNECTOR
L
L1
L0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
NC
pedestrian
General description:
the electronic control box ELPRO 37 has been developed to provide a reliable unit to control sliding gate automatic systems with or without electronic brake and limit
switches; single-phase 230 V - 50/60 Hz or three-phase 400 V - 50/60 Hz trifase. The manufacturer is not liable for any incorrect use of this appliance; and also reserves
the right to change and update it without previous notice.
IMPORTANT FOR THE INSTALLATION AND THE CORRECT FUNCTIONING:
- The control box must be installed in a dry and sheltered place; suitable holes are provided with the FADINI universal box for fitting purpose and in case any
commercial box is used, this must be adequate to the job.
- Make sure that power supply to the control board be 230 V ±10% or 400 V ±10%.
- Make sure that power supply to the electric motor be 230 V ±10% or 400 V ±10%.
- For distances longer than 50 metres increase the section of the wires.
- Fit the mains to the control box with a high sensitivity, 0,03 A, differential, magnetic-thermal circuit breaker.
- Cables with 1,5 mm² section wires are to be used for the power supply, electric motor and flasher for distances up to 50 m.
- Cables with 1 mm² section wires are to be used for the limit switches, photocells, push buttons and accessories.
- If no photocells are used link out terminals 1 and 2.
- If no stop button is used link out terminals 3 and 6.
- Open/close motor run time trimmer must be always superior to the time actually required for the gate travel.
N.W.: for applications such as light switching, CCTV, etc. use solid state relays to prevent the microprocessor from being affected.
Diagnostic LEDs:
L ON = board on 230 V or 400 V voltage and F1, F2, F3, F4, F5, F6 fuses all right
L0 OFF = pedestrian mode, it switches on by any pedestrian pulsing
L1 ON = pair photocells in closing not obstructed
L4 OFF = open, it switches on by any open pulse
L5 OFF = close, it switches on by any close pulse
L6 ON = stop, it switches off by any stop pulse
L7 OFF = radio, it switches on by any pulse from the transmitter/radio contact
L8 ON = it switches off when Fc.C (limit switch closing = L-sw.C) is engaged, M1
L10 ON = it switches off when Fc.O. (limit switch opening = L-sw.O) is engaged, M1
L33 ON = safety edge protecting closing not obstructed
L34 ON = safety edge or photocell protecting opening not obstructed
IN CASE OF FAILURE PLEASE MAKE SURE THAT:
- Power supply to the electronic control board is 230 V ±10% or 400 V ±10%.
- Power supply to the electric motor is 230 V ±10% or 400 V ±10%.
- All of the fuses is all right.
- The photocell contacts are closed.
- No voltage drop has occurred from the Elpro board to the electric motor.
- The limit switches are properly connected and work correctly.
- All of the NC contacts of the control board are all right.
SINGLE - THREE PHASE ELECTRONIC CONTROL BOARD
SLIDING GATE AUTOMATIC SYSTEMS WITH OR WITHOUT LIMIT SWITCHES
SAFETY EDGE
in OPENING
32 33 34
L33 L34
DWELL TIME
PEDESTRIAN
RUN TIME
1 s - 220 s
0 s - 120 s
1 s - 45 s
1 2
DIP-SWITCH - A
DIP-SWITCH - B
ON
ON
OFF
OFF
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4
24 Vac output
UNL
for photocell TX
enabling DSA control
E 37
UNL
L4 L5 L6 L7 L8
L10
WITH ELECTRONIC BRAKE FOR
230 V
TRANSFORMER
T.FUN
F6 = 2 A protection 24 V
EARTH CONNECTION
SETUP
JA
EDGE
TYPE
1 2
16
17
18
19 20
M1
10
400 V
F4 = 2 A transformer
and electronic brake
protection
21
22
23
NOTE:
the green LEDs must
always be on.
SYMBOLS:
NO contact
NC contact
Resistive contact
8,2 kΩ or NC
Led ON
Led OFF
Pilot light
Flasher

Publicité

loading