yellow/green earth wire must be approximately 2 cm lon-
ger than the brown (or black) phase wire.
Building In
min. 100 mm
min. 55 mm
30 mm
A) supplied seal
B) supplied brackets
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy to remove
and let an easy access in case a technical assistance inter-
vention is necessary.
www.zanussi.com
min. 650 mm
550 mm
A
B
30 mm
a
min 20 mm
60 mm
(max 150 mm)
b
a) Removable panel
b) Space for connections
Kitchen unit with oven
The hob recess dimensions must obey the indication and
the kitchen unit must be equipped with vents to let a con-
tinuous supply of air. The electrical connection of the hob
and the oven must be installed separately for safety rea-
sons and to let easy remove oven from the unit.
50 cm
360 cm
2
120 cm
180 cm 2
2
2