Peak Hold button
The.Peak.Hold.function.captures.the.peak.AC.or.DC.voltage.or.current..The.meter.can.capture.
negative.or.positive.peaks.as.fast.as.1.millisecond.in.duration...
1
Turn.the.function.switch.to.the.A.or.V.position.
2
Use.the.MODE.button.to.select.AC.or.DC.
3
Allow.time.for.the.display.to.stabilize.
4
Press.and.Hold.the.PEAK.button.until."CAL".appears.in.the.display..This.procedure.will.zero.
the.range.selected.
5
Press.the.PEAK.button,.Pmax.will.display.
6
The.display.will.update.each.time.a.higher.positive.peak.occurs.
7
Press.the.PEAK.button.again,.Pmin.will.display..The.display.will.now.update.and.indicate.the.
lowest.negative.peak.
8
To.return.to.normal.operation,.press.and.hold.the.PEAK.button.until.the.Pmin.or.Pmax.indi-
cator.switches.off.
Note:
If.the.Function.switch.position.is.changed.after.a.calibration.the.Peak.Hold.calibration.must.be.
repeated.for.the.new.function.selected.