SYSTEM MANAGEMENT FUNCTIONS
1. Deleting the entire code memory content (users)
2. Setting the master code
3. Memorising user codes locally
4. Memorising user codes remotely
5. Cancelling user codes locally
The maximum number of devices that can be connected to a single interface is limited to three.
(*)
If multiple DKSTPT or DKSDUALT devices are connected to the interface each of them must be set up with different device addresses.
1. Deleting the entire code memory content.
- Press and hold down the P1 and P2 buttons for more than 4 seconds on the interface.
- Leds L1 and L2 will remain lit for the entire duration of the deletion, which lasts for about 3 seconds.
Buzzer B1 will beep. Release the buttons.
2. Setting the master code
Interface:
- Move jumper J5 on the interface to 'position 2' then press the button P1 for at least 2 seconds.
- Buzzer B1 will beep and during the procedure led L1 will flash slowly and L2 will remain lit.
- The master code memorisation procedure will be activated with a time maximum of 30 seconds.
Keypad function DKS250T - DKSDUALT:
- Type the chosen numerical code into the keypad to enable access to the functions (max. 6 digits) and press
confirm " ". The interface will give confirmation by sounding a beep.
Transponder reader DKSTPT:
It is possible to memorise a maximum of 5 master transponder tags/cards to access the interface remotely
and manage user codes.
- On the interface, move the dips of 'S1' to 'ON' according to the table to select the memory locations.
- Move the tag/card near to the remote reader, the interface will give confirmation by sounding a beep.
If you have inserted an invalid master code the interface will sound 5 consecutive beeps.
(The master code allows the interface to be accessed remotely user codes to be managed).
6. Cancelling user codes remotely
7. Activating the user code
8. DKSTPT transponder reader setup (*)
9. DKSDUALT keypad setup (*)
10. DKS1000R interface setup
15
dip 1 dip 2
dip 3
dip 4
memory
ON
OFF
OFF
OFF
location 1
OFF
ON
OFF
OFF
location 2
OFF
OFF
ON
OFF
location 3
OFF
OFF
OFF
ON
location 4
ON
ON
ON
ON
location 5