CLEARANCES TO COMBUSTIBLES
It is of utmost importance that the clearances to combustible materials be strictly adhered to during installation
of the stove. Clearances may only be reduced by means approved by a regulatory authority. Contact your local
safety department or you may consult NFPA 211 if installing in the USA. Refer to the tables below in this section.
FLOOR PROTECTION (EMBER PROTECTION)
This heater must have a non-combustible floor protector (ember protection) installed beneath it if the floor is
of combustible material. If a floor pad is used, it should be UL listed or equal. The floor pad or non-combustible
surface should be large enough to extend a minimum of 16" [407mm] in front and 8" [204mm] on each side of the
heater. The area under a horizontal run of the chimney connector must also be protected; extending 2" (51mm)
beyond the outer dimension of the horizontal connector.
Canadian installations require a minimum of 18" [450mm] beyond the front of the unit and 8" [200mm] beyond
each side of the unit. A floor protector of 1/4" (7 mm) thick is recommended for this installation.
FLOOR PROTECTOR
The minimum sized floor protector for this stove is 41.8" X 35.4" (1062mm X 900mm) [Canada 43.8" X 35.4" (1113mm
X 900mm)]. Consult local building codes and fire protection ordinances.
Single Wall Pipe
Key
Stove to:
in
A
Backwall
8
B
Side Wall
8
C
Corners
8
Ceiling
D
84
Height
E
Sidewall
15
F
Backwall
23
G
Corners
21.4
Floor Protection
Edge to
Key
in
Stove:
Stove
H
19.4
Width
Stove
I
23.8
Depth
16
J
Front
(CAN 18)
K
Back
2
L
Side
8
Side of
M
2
Venting
mm
204
204
204
2134
381
585
544
mm
493
605
407
(CAN 458)
51
204
51
-5-