PLASMA CUTTER 85A / 125A
One phase is missing
Overvoltage detected on the network
Network voltage is too low (-15%)
Network voltage is too high (+15%)
Network voltage is out of range (+/-20%)
Upper secondary thermal protection unplug-
ged
Lower secondary thermal protection unplug-
ged
Primary thermal protection unplugged
PWM controller protection
No air
Pressure too low
Low pressure
No torch
Shroud disconnected
Trigger pressed
Faulty fan
Two torches detected
Communication error between micro control-
lers.
Torch interior contact detection default
Pilote arc fault
Pilot arc opening fault
System default
The machine has detected that at least one
phase is missing. Unplug the machine and
check your electrical distribution network.
An overvoltage was detected on the electrical
distribution network. The machine is pro-
tected. Unplug the machine and check your
electrical distribution network.
The machine indicates that the network
voltage is close to the maximum authorised
range. If this happens while powering up, the
machine will stop. Unplug the machine and
check your electrical distribution network.
The maximum voltage range has been
reached, the machine switched off to protect
itself. Unplug the machine and check your
electrical distribution network.
One of the thermal protections in unplugged.
Have a qualified technician check it.
PWM controller has encountered an error.
The machine requires a reparation.
Check that the air pipe is correctly connected
to the device or that the pressure is com-
prised between 5 and 9 bars.
The device has stopped cutting because the
air pressure has become too low to perform
a cut. Check your air supply.
The machine signals that the air pressure is
becoming low but still performs a cut. Check
your air supply.
The torch is disconnected. Connect a torch
and restart the machine.
The shroud is not detected. Unplug the
machine, reinstall the consumables and
restart the machine.
The trigger was detected as «pressed» while
starting the machine.
The cooling fan test has encoutered an error.
Check that the ventilation fan works.
Both torch types were detected at the same
time. Check that your torch is compatible.
An internal communication error has been
detected. Restart the product. Have a
qualified technician check the connections
between the front PCB and the main PCB if
the error keeps occuring.
Pilot arc installation fault. The consumables
did not revert to their place.
Pilot arc installation fault. Pilot arc current
not detected.
Pilot arc installation fault. The arc pilot is not
detected.
A sytem error has occurred. The machine
requires a reparation.
EN