ENGLISH
Before commencing with the installation of this appliance make sure that you have read the following instructions carefully. In
particular familiarise yourself with the safety devices required by the system, only then will you be able to use them to great effect.
Not all of the safety devices required by Italian or local safety standards have been taken into consideration in this manual. The
installer must therefore make sure that any eventual safety devices required by the local standards and regulations have been
installed both ahead of and after the products described in this manual. These instructions are aimed at professionally qualified
"installers of electrical equipment" and must respect the local standards and regulations in force . This appliance must be used
exclusively for the purpose for which it has been made. "i.e. for the automation of gates and doors" Any non authorised modifica-
tions are to be considered improper
TECHNICAL SPECIFICATIONS
Power supply
Frequency
Number of possible motors
Overall motor power
Nominal electrical input
Operating temperature
Inputs
Power supply connection 230Vac 50/60Hz
Earth wire
Antenna entry point for slot-in receiver card
Opening button in input "normally open contact"
Limited opening button in input "normally open contact"
Closing button in input "normally open contact"
Dynamic button in input "normally open contact"
Blocking button in input "normally closed contact"
Inversion photoelectric cells "normally closed contact"
Blocking photoelectric cells "normally closed contact"
Opening/closing "1" travel limit "normally closed contact" (can be excluded via software)
Opening/closing "2" travel limit "normally closed contact" (can be excluded via software)
Outputs
Output motor 1
Output motor 2
Output for warning lights 230Vac 40W (intermittent or continuous operation)
Output for a timer controlled night light 230Vac 40W
Output powering external devices 24Vac 10W
Output for electric locking device 12Vac 15W
Output for indicator lamps 24Vac 3W
Output for radio receiver second channel contact C-NO (only with a 2-channel receiver card)
Work time: Maximum programmable time
Pause time: Maximum programmable time
Night lights
For a double leaf installation the overall time is equal to: "work time leaf 1 + leaf 2 + pause time + 30 seconds"
For a single leaf installation the overall time is equal to: "2 times the work time of leaf 1 + pause time + 30 seconds"
Function description
Electronic programmer for single/double leaf gates, sliding, hinged or garage doors running off 230Vac. The use of voltage partiali-
zation applied to the motors allows initial thrust and torque limiter control.
Setting the system functions is carried out simply using two buttons, which activate a ten stage programming sequence; a 7-seg-
ment LED display guides the installer through the selection of the following options:
1.
Single/double gate leaves
2.
Sliding/hinged gates
3.
Electric lock freeing movement (gate jolt)
4.
Electric lock
5.
Dynamic button function mode
(open-block-close-block /open-close-open-close
Following on from this the torque limiter can be set and then the work time programming which is executed in real time (the motors
move while the work time is being set).
Limited opening can only be set for gate 1 (motor M1) which is also the first to open when you have a double hinged gate installa-
tion; the work time is equal to the complete time for gate 1.
REMARKS
300 seconds
300 seconds
6.
Automatic reclosing
7.
Preflashing
8.
Gate 1 travel limit exclusion
9.
Gate 2 travel limit exclusion
0.
Intermittent flashing warning light activation
12
ENGLISH
Vac
230
Hz
50/60
Nr.
2
W
470 + 470
Amp
4.6
°C
-20...+55