User Instr u cti o n s - En g l i s h
Step 5
With webbing straps oriented in the center, close webbing retainer clip.
Webbing must be
captured by
connector carabiner
and retainer clip.

5.0 Use

Once the Twin Turbo G2 Fall Protection System has been properly assembled and connected
to an approved anchorage. Anchorages must be capable of supporting a 5,000 pound (22.2kN)
person as part of a complete fall arrest system which maintains a safety factor of two. Make sure
strength and shape. Always verify that the connector gate is completely closed and locked.
While the Twin Turbo G2 System is designed to provide a user with two connecting devices for
be connected at the same time when transitioning from one anchorage to another. During the