No.
Signal
1
FG
2
DRAWER1
3
DRSW
4
VDR
5
DRAWER2
6
GND
* Applicable connector: RJ-11
(2) Electric characteristics
1) Drive voltage: 24 VDC
2) Drive current: Approx. 1 A max. (not to exceed 510 ms.)
3) DRSW signal: Signal levels: "L" = 0 to 0.5 V, "H" = 3 to 5 V
(3) DRSW signal
Status can be tested by commands.
(4) Drive circuit
Cash drawer
open/close
switch
n Cash drawers 1 and 2 cannot be operated at the same time.
n The solenoid used for the cash drawer should be 24 Ω or more. Do not allow the electric cur-
rent to exceed 1 A. Excessive current could damage or burn out the circuits.
Frame ground
Cash drawer 1 drive signal
Cash drawer switch input
Cash drawer drive power supply
Cash drawer 2 drive signal
Signal ground (common ground on circuits)
Cash drawer kick-out connector
Shielded
Cash drawer
CAUTION
– 63 –
Function
Printer