Parts List
Description
A wall plate
B wall plate cover
C speaker mounting bracket
D horizontal arm
E arm connector
F small end cap
G large end cap
H M6 x 12mm phl
I M6 x 8 set screw
J M8 x 35mm phl
K height adjustment knob
L M8 x 65mm bolt
M M8 nylock nut
N plastic washer
O foam strip
P M6 concrete anchor
Q M6 x 50mm wood screw
R 3mm allen wrench
A ( 2 )
wall plate
H ( 4 )
M6 x 12mm
O ( 4 )
foam strip
ENG
ESP
FRN
Qty
2
2
4
2
2
4
2
4
4
2
2
2
2
4
4
8
8
1
B ( 2 )
wall plate cover
I ( 4 )
M6 x 8mm
set screw
L ( 2 )
M8 x 65mm
P ( 8 )
M6 concrete anchor
C ( 4 )
speaker bracket
F ( 4 )
sm. end cap
J ( 2 )
M8 x 35mm
R ( 1 )
3mm allen wrench
M6 x 50mm hex wood screw
1
26 lb
MAX
(12 kg)
G ( 2 )
lg. end cap
M ( 2 )
M8 nylock nut
plastic washer
K ( 2 )
height adjustment
knob
Q ( 8 )
2016-08-25
D ( 2 )
horizontal arm
E ( 2 )
arm connector
N ( 4 )
#:204-9049-1

Publicité

loading

Sommaire des Matières pour peerless-AV SPK26

  • Page 1 Parts List Description A wall plate B wall plate cover C speaker mounting bracket D horizontal arm 26 lb E arm connector (12 kg) F small end cap G large end cap H M6 x 12mm phl D ( 2 ) I M6 x 8 set screw horizontal arm J M8 x 35mm phl...
  • Page 2 WARNING ENG - This product is designed to be installed on wood stud, solid concrete or cinder block walls. Hardware is included for wood stud, solid concrete and cinder block installation. Before installing make sure the supporting surface will support the combined load of the equipment and hardware. Screws must be tightly secured. Do not overtighten screws or damage can occur and product may fail.
  • Page 3 Wood stud wall. Concrete/Cinder block. Pared de madera. Concreto/Bloque de hormigón. Mur en bois. Béton/bloc de béton. WARNING ENG - When installing Peerless wall mounts on a wood stud wall covered with gypsum board (drywall), verify that the wood studs are a minimum of 2" x 4" nominal size. Do not install over gypsum board thicker than 5/8". ADVERTENCIA ESP - Cuando vaya a instalar soportes de pared de Peerless en paredes con montantes de madera recubiertas con yeso-cartón (gypsum board) verifi...
  • Page 4 1a-3 2.5" (64mm) 1/8" 1/8" (3mm) (3mm) Drill mounting holes into supporting surface (2.5" (64mm) minimum depth required). Taladre los agujeros de montaje en la superfi cie de apoyo; se requiere una profundidad mínima de Mounting hole must center on stud. 2.5"...
  • Page 5 WARNING ENG - When installing Peerless wall mounts on a concrete wall, the wall must be at least 8" thick with a minimum compressive strength of 2000 psi. When installing Peerless wall mounts on a cinder block wall, the cinder blocks must meet ASTM C-90 specifi...
  • Page 6 1b-2 2.5" (64mm) 5/16" 5/16" (8mm) (8mm) Drill mounting holes into supporting surface (2.5" (64mm) minimum depth required). Taladre los agujeros de montaje en la superfi cie de apoyo; se requiere una profundidad mínima de Do not drill into mortar joints. 2.5"...
  • Page 7 1/2" (13mm) 3/8" (10mm) N (2) H (2) O (2) C (2) I (2) F (2) 2016-08-25 #:204-9049-1...
  • Page 8 Ajuste de la inclinación: Apretar o afl oje. +/- 35° Réglage de l'inclinaison : Serrer ou desserrez. SPK26 Peerless-AV Peerless-AV Europe Peerless-AV de Mexico 2300 White Oak Circle Unit 3 Watford Interchange, Ave de las Industrias 413 Aurora, IL 60502 Colonial Way, Watford, Herts, Parque Industrial Escobedo Email: tech@peerlessmounts.com...