TECHNICAL SPECIFICATIONS OF PRODUCT COMPONENTS

CLB207 is manufactured by NICE S.p.A. (prov. of Treviso – Italy). Nice S.p.A., in order to improve its products, reserves the right to modify their
technical specifications at any time without prior notice. In any case, the manufacturer guarantees their functionality and fitness for the intended
purposes. Note: all technical specifications refer to a temperature of 20°C.
Control Unit
Product type
Technology adopted
Max. cycles frequency
Power supply
Absorbed rated power
Emergency power supply
Motor outputs
Flashing light output
ECSbus output
"SbS" input
"STOP" input
Radio aerial input
Max. cable length
Ambient operating temperature
Assembly
Protection rating
Dimensions / weight
Possibility of remote control
Compatible ECCO5... transmitters
ECCO5... transmitter range
Programmable functions
Self-programmed functions
CLB207
Assembly Protection rating Dimensions / weight Control unit for 1 or 2 24V
mation of automatic gates or doors, complete with radio receiver for "ECCO5..." transmitters
Electronic board governed by 8-bit microcontroller with flash technology
A transformer incorporated in the control unit, but separated from the board, reduces the mains
voltage to the nominal 24 V voltage used in the whole automation system
30 cycles/hour
230V
(+10% -10%) 50/60Hz
70W; on start-up power is 160W for a maximum time interval of 2s
For "PR100" buffer batteries
2, for 24V
motors with nominal current of 1.1A, on start-up, maximum current is 3.5 A for a
maximum time interval of 2 s
For flashing lights with 12V (maximum 21 W) bulb
1 output with maximum load of 15 ECSbus units
For normally open contacts (closure of the contact prompts the "Step-by-Step" command)
For normally open and/or 8,2kohm constant resistance type contacts, or normally closed con-
tacts with self-learning of the "normal" status (a variation with respect to the memorised status
generates a "STOP" command)
50 ohm for RG58 or similar type cable
Mains power supply: 30 m; motors outputs: 10 m; other inputs/outputs: 20 m with antenna cable
preferably shorter than 5 m (observe the warnings regarding minimum gauge and type of cables)
-20°C ... 50°C
Vertical, wall-mounted
IP44
180 x 240 h 110 mm / 2.8 kg
Using "ECCO5..." transmitters, the control unit is able to receive one or more of the following
commands: "Step-by-Step", "Partial Open", "Open Only" and "Close Only"
Up to 256 if memorised in Mode 1
From 50 to 100m. This range can vary if there are obstacles or electromagnetic disturbances,
and is affected by the position of the receiving aerial incorporated in the flasher
"Single cycle" or "Complete cycle" (automatic closure) operating mode
Motor speed "low" or "high"
Pause time in "complete cycle" selectable from 10, 20, 40, and 80 seconds
Type of partial opening selectable from 4 modes
Obstacle detection system sensitivity selectable on 4 levels
"Step-by-Step" command functionality selectable in 4 modes
Self-learning of devices connected to the ECSbus output
Self-learning of type of "STOP" device (NO, NC or 8.2 kΩ resistance contact)
Self-learning of manoeuvre length for each motor
Automation autodetection with 1 or 2 motors
motors for auto-
English – 21