TROUBLESHOOTING CHART
Problem
The product does not
start.
The product runs, but
delivers no water.
Pump capacity too low.
The product makes a
noise.
24
Possible cause
No power supply.
Overheating, usually because
the temperature of the water is
too hot.
Blockage.
The residual current device has
tripped.
Motor malfunction.
The suction tube is blocked.
The product sucks air.
The product is blocked by a
foreign object.
The delivery height is too high.
The diameter of the outlet tube
is too small.
The outlet tube is blocked.
The suction tube is blocked.
The outlet tube is bent.
Outlet tube is leaking.
Air in the product.
Action
Check the power cord, plug, power
point and fuse.
Identify and rectify the reason.
Clean the filter.
Reset the residual current device.
Contact an authorised electrician if
the residual current device continues
to trip.
Contact an authorised service centre.
Remove the blockage.
Make sure that all the connections
are airtight.
Clean the filter.
Do not exceed the maximum delivery
height.
Use an outlet tube with a suitable
diameter.
Remove the blockage.
Clear the suction tube.
Straighten out the outlet tube.
Make sure that the outlet tube and all
the connections are tight.
Fill the product full of water. Make
sure that all the connections are
airtight.