Circuit board fuse
Replaceable fuse: 3.15 A T
The fuse only needs replacing if the green LED [V] is not lit up.
See "Fig. 23" on page 37
See "Fig. 23" on page 37
5.5.3
Dipswitch for time mode settings
Fig. 25
5.5.4
Stripping the cable
The cable for the power supply should be stripped to a length
of 15 – 17 cm.
5.6
Disassembly
1.
Loosen cable screw (20) and disconnect floodlight from the
control box.
2.
Loosen air regulator (21/1) by turning it anti-clockwise.
3.
Unlock and remove pneumatic button (38/1; 38/2) by turning
it anti-clockwise.
4.
Loosen screws (49).
5.
Loosen screws (95.1).
6.
Remove cover (93).
7.
Loosen screws (95) and remove nozzle housing (102.1).
8.
Loosen screws (52), support ring (28) and support ring seal
(27).
08|2020
Installation
EN 39