Problem: Pump leaks.
Possible cause
Mechanical seal is worn or
damaged.
Problem: Loud motor noise.
Possible cause
Faulty ball bearings.
Direction of rotation is wrong
(3~).
Problem: No water jet despite the unit being turned on.
Possible cause
Air in the system.
Leakage in the suction line.
08|2020
Solution
Have a professional
replace the mechanical
seal.
Solution
Have a mechanic replace
the ball bearings.
Have a qualified
electrician check it.
Solution
Tighten screw
connections.
Replace the seals.
Tighten screw
connections.
Check for leaks.