Set the output voltage of output B
Output B can be used independently from output A.
Remove the connected consumer from output B (9 and 10).
Switch on the mains power supply at the power switch (1). The operating display (2) lights up and the
current and voltage display appears on the display.
Press the button „show value" (8) and keep it pressed while setting the voltage. The display of output A
shows the voltage and current of output B.
Via the rotary control „V-adjust" (7) you can set the output voltage for output B.
After setting the voltage, let go of the button (8) again.
A fixed current limit of approx. 1.5 A is set for output B, which cannot be changed.
When this current limit is reached, the red indicator "overload" (6) lights up.
You can check the corresponding voltage and current values at any time by pressing
the button „show value" (8).
Connecting a Consumer
When connecting a consumer, make sure that it is connected to the power sup-
ply when switched off. The maximum current consumption of the device to be
connected must not exceed the capacity indicated in the technical specifica-
tions.
For series connection of several power supplies outputs, contact dangerous volt-
ages (> 75 VDC) are created where contact can be fatal. From this voltage, you
may only use insulated accessories (connection cables, measurement cables
etc.)
Avoid the use of non-insulated metallic cables and contacts. All these spots
must be covered with suitable, flame-resistant insulation materials or by means
of other measures, which serve to prevent direct contact and short circuits.
Ensure a sufficient cable diameter for the intended current.
25