World Dryer Operating Instructions and Parts Manual
World Dryer Airmax
E
N
G
Installation
L
FOR MODELS (D)M5, 54, 548
I
1. Disconnect the power source.
S
H
2. Use the security Allen wrench
supplied to remove the (2) cover
mounting screws. Remove the
cover from the dryer.
3. Place the hand dryer base on the wall
at the desired location using Table 1
to determine the recommended
mounting height. With the base so
located, use it as a template to mark
locations of the 4 mounting bolt holes
on the wall. When two or more
dryers are installed, they should
be spaced 24" (61 cm) minimum
from center to center.
4. Fasten the base to the wall, using the
type of bolts suggested in Table 2.
5. Connect the dryer to the nearest
suitable distribution panel.
6. Replace cover, making certain not
to over-tighten cover bolts.
FOR AUTOMATIC DRYER
MODELS (D)XM5, 54, 548
1. Disconnect the power source.
2. Use the security Allen wrench
supplied to remove the (2) cover
mounting screws. Remove the
cover from the dryer.
NOTE: When using surface mount wiring, an optional, available offset fitting #100BR must be ordered to adapt the wiring to
1/2" EMT.
Type of Wall
Hollow Tile, Lath, Wall Board or Metal
Cement, Brick, or Tile Covered Cement or Brick
Stud Wall with Wood Backing
Table 2
™
3. Place the hand dryer base on the wall
at the desired location using Table 1
to determine the recommended
mounting height. With the base so
located, use it as a template to mark
locations of the 4 mounting bolt holes
on the wall. When two or more
dryers are installed, they should be
spaced 24" (61 cm) minimum from
center to center. Applies only to
the Automatic models: ensure that
no reflective object (such as a hand
basin) is located directly under the
infra-red sensor eye; the minimum
distance is 18 inches.
4. All automatic dryers must have their
own dedicated 20 amp circuit. This
is a UL-suggested requirement.
IMPORTANT: Consult local and
general regulations before performing
dryer installation. Ensure that the
electrical network is not overloaded.
Do not connect to a branch circuit
over 20 amps.
Maintenance
1. Remove fuse or shut off power to
the dryer at fuse box.
2. With security Allen wrench supplied
with dryer, remove two Allen screws
from bottom side of dryer case.
3. Remove dryer cover.
Type of Bolt
1/4" (M6) Screw Type or Wing Type Toggle Bolts
1/4" (M6) Stud Type Expansion Bolts
No.16 (M8) Wood Screws
2
Hand Dryers
CLEANING INSTRUCTIONS
Read complete Instructions before
proceeding. Under normal use, cleaning
the Dryer once a year will keep it in
good operating condition. If the wash-
room traffic is heavier than normal,
the cleaning should be done every 6
months. Lint and dust build up inside
the dryer can result in damage to motor
and heating element as well as hot
emissions that could injure the user.
1. Turn off dryer at circuit breaker or
fuse panel.
2. Remove two cover mounting screws
from dryer cover using security Allen
wrench provided. Support cover while
removing screws.
3. Remove three (3) side screws holding
blower housing together. Note posi-
tion of heating element. The lead
wires are directed through the
clearance hole in the blower housing
halves. Carefully remove the heating
element however, do not disconnect
the wires.
4. Clean blower wheel halves using a
1/2" diameter radial bristle brush.
Insert brush through space between
individual blades and dislodge dirt.
Do not bend blades.
Minimum Bolt Length
Dependent on wall thickness
3" (76 mm)
2
/
" (70 mm)
3
4
(D)XM and (D)M