Télécharger Imprimer la page

Team kalorik TKG SKV 1004 Mode D'emploi page 11

Aspirateur 2 en 1 à filtration à eau

Publicité

Fax +32 2 359 95 50
Turn the inner tube (6) counterclockwise to remove it (Ill. 10, Fig. 15); you can also refer to
the marking. Clean the lid, tube, inner tube and textile filter with clean water and let
everything dry thoroughly before reassembling and installing the water tank.
Lay the vacuum cleaner flat on the floor to disassemble the floor brush (6). To do this, press
the release switches (5a, 5b) simultaneously (Ill. 11, Fig. 16).
Clean the dust container of the hand vacuum cleaner after each use. Remove the dust
container from the engine block by pressing the release button (2). We recommend that
you do this over a trash can (Ill. 9, Fig. 10).
Remove the filter holder (6) and filter cartridge (7) by turning it counterclockwise (Ill. 9, Fig.
11). Tap the filter cartridge and clean the filter holder under running water (Ill. 9, Fig. 12).
Allow all parts to dry before reassembling.
Cleaning the filter and the dust container is very important, as it allows the device to
operate optimally and eliminates unpleasant odors.
Manually rotate the mobile element of the floor brush regularly to remove any foreign
objects that may be stuck (Ill. 12).
If the moving element does not rotate (Ill. 13), pull back the switch on the left side of the
brush (a) and remove the roller (b). (Ill. 13, Fig. 18). Remove dirt and grime. When using a
pair of scissors, be careful not to injure yourself or cut off the brushes (Ill. 13, Fig. 19 & 20).
Put the roller back in and check if it can be easily moved manually (Ill. 13, Fig. 21)
Note: After each use, check that the brush still rotates smoothly.
TROUBLESHOOTING
Problem
The vacuum cleaner does not
turn on
The vacuum cleaner is not
charging
The suction power is decreasing
Vacuum cleaner is overheating
The air coming out of the
vacuum cleaner smells bad
The battery/ charging indicator
light is blinking
The brush does not turn
anymore
Copies of the I/B. Please reproduce them without any changes
except under special instruction from Team International BELGIUM.
The pages must be reproduced and folded in order to obtain a
booklet A5 (+/- 148.5 mm width x 210 mm height). When folding,
make sure you keep the good numbering when you turn the pages
of the I/B. Don't change the page numbering. Keep the language
integrity.
Possible cause
The vacuum cleaner has not
been charged
The power switch is not turned
on
The power cord is damaged
The crevice tools or extension
hose may be blocked
The water in the water tank is
very dirty
The filter is dirty
The filter is dirty
The filter is dirty
The filter is not dry
The vacuum cleaner is out of
power
The brush is dirty
11
Assembly page 11/28
Solution
Make sure the vacuum cleaner
has been fully charged before
first time use or if it has not been
used for a long time
Make sure the power switch of
the main power supply is turned
on
Do not use a damaged power
cord. Please contact the
customer service center
Check for any blockages and
clear them
Regularly replace the water in
the reservoir by clean water and
empty the water tank after each
use
Check with the supplier for
replacement parts
Check the filter and clean off any
dirt
Check the filter and clean off any
dirt
Make sure the filter is dry before
inserting it back into the hand
vacuum cleaner. Replace the
water with clean water if needed.
Recharge the vacuum cleaner to
its full capacity. The light will
stop blinking.
Clean the brush
TKG SKV 1004 - 180329

Publicité

loading