G
B
7.3 Pulse operation (DIP 4)
The setting of this dip configures the operating mode, when the DIP 1 and the DIP 2 are set to ON (impulsive command).
ON
OFF
DIP
2 3
4
ON
OFF
2 3
4
DIP
The "GO" function is automatically excluded with the DIP 1 and/or the DIP 2 to OFF .
8. Procedure for setting up the automatic closing time.
The pause time before the automatic closing can be set between 1 to 60 s.
You can enable / disable automatic closing and save its value by doing the following:
1) Stop the operator.
2) Press the RADIO LEARN button on the control panel for more than 5 s => The panel emits a double beep repeatedly.
3) Release the RADIO LEARN button
4) Set the pause time before the automatic closing time 1s ÷ 60s by turning the RUN TIMER trimmer
➡
Turn clockwise the "RUN TIMER" trimmer to increase the
-
+
automatic closing time.
RUN TIMER
5) Press and release the RADIO LEARN button to confirm the selected time => The box will confirm the memorization of the selected time with an extended beep.
Note: Once this procedure is finished, you should set the working time as indicated in section 8.1.
Automatic closing time exclusion procedure.
1) Stop the operator.
2) Press and hold the RADIO LEARN button in the control board for more than 5 s => The control board will emit a double beep repeatedly.
3) Release the RADIO LEARN button
4) Turn the RUN TIMER trimmer counterclockwise to disable the automatic closing (minimum).
5) Press and release the RADIO LEARN button to confirm the option. The control board will emit a series of quick beeps to confirm the exclusion of the automatic closing time.
Note: Once this procedure is finished, you should set the working time as indicated in section 8.1.
Situations where the automatic closing time is prevented.
In the full open position (equivalent to the end of the working time), the countdown of the automatic closing time is interrupted and the automatic closing time starts again from the beginning
under the following conditions:
- if the STOP button is pressed and/or when the PHOTOCELLS beam is cut by an obstacle.
- if the OPEN button is pressed and held and the "dead man control" has been selected (DIP 1 OFF).
8. Working time adjustment
It enables to set the operation time of the automation. The time can be set for values between 1,5 s and 90 s.
The working time is excluded in case that the dead man function is activated.
➡
Turn clockwise the "RUN TIMER" trimmer to increase the working
-
+
time.
RUN TIMER
The "GO function" is activated.
The automation works under "step by step" mode with one button.
The OPEN/"A" button of the remote control makes the sequence open-stop-close.
The "B" button of the remote control can be used to control another automation.
The open– close function with two buttons is activated.
Pressing the button OPEN/"A" button of the remote control the automation opens.
During opening, pressing the button CLOSE/"B" button of the remote control the automation stops.
Pressing the button CLOSE/"B" button of the remote control the automation starts closing.
Turn counter clockwise the "RUN TIMER" trimmer to decrease the
automatic closing time.
Turn counter clockwise the "RUN TIMER" trimmer to decrease the
working time.
20
⬅
-
+
RUN TIMER
⬅
-
+
RUN TIMER