Télécharger Imprimer la page

Aircare MA1201 Manuel D'utilisation Et D'entretien page 7

Publicité

Les langues disponibles

Les langues disponibles

The SET readout has a range of 25% to 65% and is adjusted in increments of
5%. Initially depressing the humidity button will display the current humidity
setting. Each additional press of the button increases the setting by 5%. A SET
point of 65% operates the humidifier continuously regardless of the ROOM
reading.
SPEED CONTROL
The letter "A" appears when the auto humidistat is selected. This setting allows
the auto humidistat to select the fan speed necessary to maintain the desired
humidity level.
The selected setting is displayed on the digital readout. The higher the setting,
the faster water is evaporated and released into the air. F1 (Ultra Quiet) is the
quietest setting and is provided for conditions that do not require a rapid
evaporation rate.
* Humidifier fan should operate at initial start-up. If it does not, refer to, "Fan not
operating (digital display is illuminated)" in the "Trouble Shooting" section.
OTHER FEATURES / INDICATIONS
CHECK FILTER
The ability of any humidifier to efficiently supply humidity output relies heavily on
the condition of the filter. As the filter loads with impurities it gradually loses its
wicking capability. When this happens, moisture output is reduced and the
humidifier has to work longer to satisfy the selected setting.
1) This humidifier has a check filter reminder timed to appear
after 720 hours of operation. When the Check Filter (CF)
message is displayed, disconnect the power cord and check
the condition of the filter. If a build-up of deposits or severe
discoloration is evident replace the filter to restore
maximum efficiency.
The CF function is reset after plugging the unit back in.
2)
When the unit is out of water, a flashing F will display on
the display panel.
AUTO DRYOUT
At this time the unit will automatically switch into AUTO DRY
OUT MODE and continue to run on the lowest speed until the
filter is completely dry. The fan will shut off leaving you with a
dry humidifier that is less prone to mold and mildew.
During the AUTO DRYOUT mode the room humidity level will continue to be
monitored and the humidifier will cycle the fan on and off until the filter is
completely dry.
This humidifier is equipped with a
4-speed fan control.
Initially depressing the speed button
will display the current speed
setting. Each push of the speed
button advances the mode through
the settings of (HIGH) F4, (MEDIUM)
F3, (LOW) F2, and (ULTRA QUIET) F1.
7

Publicité

loading