Side Floor Exhaust
C L

Duct Connections

• Blower exhaust faces towards rear wall from factory.
Blower can be changed to exhaust to left. Connect
blower exhaust to ducting with 3¼ x 10-inch piece.
• Do not install 2 elbow fittings next to each other. Two
elbow fittings joined together create unusual air
patterns and can result in poor ventilation.
• Do not vent into an attic or crawl space. Always vent
outside.
• Seal all joints in venting system with duct tape to
avoid smoke or odor in home.
• Do not use laundry wall caps. Wall cap must have
minimum of 28 square inches free air space. Use
Amana wall cap model CC30.
Vertical and Left Duct Connection
To vent out left wall or vertically, remove vent filler
piece and move to rear of blower.
1. Remove 4 screws that attach vent filler.
• See illustration.
2. Place vent filler on left side of blower housing.
3. Attach vent filler with 4 screws.
Horizontal Rear Duct Connection
To vent out rear wall, do not move vent filler piece.
Left
exhaust
Blower housing front
Blower Housing
8
Rear
exhaust
Vent filler piece