Télécharger Imprimer la page

Ribimex Ribitech PRDECA2000 Manuel D'instructions Et D'utilisation page 17

Publicité

Les langues disponibles

Les langues disponibles

If the power cable or extension cord is damaged or cut during operation, immediately disconnect plug
from its main power source. Do not touch the cable or extension cord before unplugging from main
power.
11. Remarks:
The safety precautions and instructions given in this manual are unable to cover in detail all the
conditions and situations that may arise.
The operator and/or user must use common sense and caution when operating the product especially
for any matters that are not referred in the above
IV. GETTING STARTED
Before any intervention on product, ensure that switch is off and plug is
disconnected from its power source.
4.1- Unpacking
Remove product from its packaging.
Check that tool and accessories are not damage.
4.2- Inserting and removing a nozzle
Only on PRDECA2000KIT/311019
- To install a nozzle
Insert accessory nozzle on main nozzle and ensure it is centered and properly fixed.
- To remove an accessory nozzle from the main nozzle: ensure the accessory nozzle is cooled down
and pull it out firmly
4.3- Switch On/Off
4.3.1- For PRDECA2000/311026
The switch (2) has 3 positions « 0 » (Off) and « I » , « II » (On).
To start the tool: position the switch on « I » or « II ».
To stop the tool: position tool on « 0 »
4.3.2- For PRDECA2000KIT/311019
The switch (2) has 4 positions « 0 » (Off) and « 1 », « 2 » et « 3 » (On).
To start the tool: position the switch on « 1 » or « 2 » or « 3 ».
To stop the tool: position tool on « 0 »
4.4- Heat and air flow adjustment
You can adjust the temperature and air flow through the settings of the switch
Switch position
Temperature
Air flow
Note : on PRDECA2000KIT/311019, the temperature can be adjusted through the knob (7) located
on the rear side of the tool.
Position the main switch on « 2 » or « 3 », then adjust the temperature by rotating the knob
(settings from 1to 9) to regulate the temperature (see table above).
Warning: let tool and nozzle cool down before any intervention or before storing it.
PRDECA2000/311026
I
II
450C
600C
300 l/min
500 l/min
PRDECA2000KIT/311019
1
2
50C
50-450C
250 l/min
250 l/min
3
50-600C
500 l/min
Page 17 / 28

Publicité

loading

Ce manuel est également adapté pour:

Ribitech prdeca2000kit311026311019