D. REACTOR INSTALLATION
The Elektra UV unit comes with all internal components fully assembled and ready for installation.
Your Elektra UV unit will need to be plumbed into your pond or swimming pool circulation
Reminder: We recommend the presence of a by-pass.
The inlet for the water is at the bottom of the Elektra UV unit.
The SOLID COLOR union tail piece is used on the BOTTOM union.
The outlet for the water is at the top.
The CLEAR union tail piece is used on the TOP union.
Also packed with your Elektra unit are two white gaskets that are used to complete the Inlet/Outlet unions.
1) Install the union tail pieces by screwing them into the union nuts on the Elektra unit.
2) DO NOT OVERTIGHTEN (hand tightening is sufficient). Overtightening will break the
union nuts.
ELECTRICAL BONDING (GROUNDING)
ELECTRICALLY BONDED TO A COMMON GROUND.
DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit
The unit should be installed and grounded by a professional service
technician or similar person, qualified in electrical equipment installation
V4 Elektra EA Anglais.doc
Marque, Modèles et Brevets déposés - Produits exclusifs
Inlet / Outlet Unions
Heating
(swimming
pool)
FILTER
PUMP
THE EQUIPMENT MUST BE IMPERATIVELY
SLAVED TO THE FILTRATION.
ALL COMPONENTS (pump, filter, EA unit) MUST BE
protected by a Ground Fault Circuit Interrupter.
OUTLET
VALVE
BY-PASS
VALVE
INLET
VALVE
system.
.
Copyright DELTA UV
Page 7