1) Inspect Heated Accessory to ensure it is in good shape (no rips or tears in fabric).
2) Follow steps 1 - 3 in the section "B - Unit Installation" in the manual that came with your Fendall 2000 unit but using
the bracket provided with the Heated Accessory instead.
3) Hang the Heated Accessory from the bracket opening located on the back. Open up the Heated Accessory by unzipping
the zipper on the left side of unit and opening the top and bottom flaps. Replace insulation onto bracket. (Fig. 1)
4) Hang the Fendall 2000 unit on the bracket as instructed by steps 4 - 6 in the section "B - Unit Installation" in the
manual that came with your Fendall 2000 unit.
5) Follow steps 1 - 9 of the manual, "Fendall 2000™ Cartridge Quick Installation", that came with your cartridge.
6) Close up the Heated Accessory by zipping it up, snapping buttons, and securing the Velcro™ on everything besides the
front door. (Fig. 2)
7)
Open the door and pull the head rest towards you.
8) Pull the headrest forward and then
making sure the tube is not twisted and that the small locking hub of the wire tie is facing towards the inside of the
unit. Push the headrest back to it's original position until an audible 'click' is heard.
9) Place the inner strap of the
the strap will not interfere with the nozzle snapping into the unit's door. (Fig. 3)
10) Close the unit and Heated Accessory door while holding the inner strap until an audible 'click' is heard. Firmly close
the door by making sure the Velcro™ around the door is fully secured. Also, make sure to tuck the top of the Front
Door under the Top Flap.
11) Plug the unit into a power source (there is a GFCI built-in for your safety and convenience). Push the reset button on
the GFCI to re-enable the circuit.
Bracket
opening with
insulation
Bottom Flap
Fig. 1
Sperian Eye & Face Protection, Inc. • 825 East Highway 151 • Platteville, WI 53818 USA • 1-800-336-3255
Heated Accessory Installation
™
Package should include the following:
• Fendall 2000 Heated Accessory
• Mounting bracket with insulation
• Installation Manual
• Warranty Card
NOTE:
Mounting hardware is needed to secure bracket to
the wall or stand (screws, bolts, anchors, etc.); not included
pull out the nozzle from the basin. Slide the nozzle into the nozzle compartment,
Heated Accessory's door over the unit door but holding it towards the top to ensure that
Top Flap
Part # 32-005684 Rev. A
Front Door
Fig. 2
# 32-002001-0000