11
Annex
11.1 Information required by the Ecodesign Directive
The heating element is controlled either by the VTX series
control system or by the VTD-UP room thermostat.
Control system of the VTX series: The heating element is
switched by the VTX-E or VTX-EU radio receiver. The room
temperature is measured by the battery-operated VTX-SP
room thermostat. With the heat-up function activated, the
comfort temperature programmed in the weekly
programming is reached at the set point in time, since the
thermostat controls the heating start adaptively. Open
Designation
Heat output
Nominal heat output
Nominal heat output
Minimum heat output
Max. cont. heat output
Auxiliary power consumption
For nominal heat output
For minimum heat output
In standby mode
Specification
Type of heat output/room temperature control (please select one option)
single stage heat output, no room temperature control
two or more manually adjustable levels, no room temperature control
room temperature control with mechanical thermostat
with electronic room temperature control
electronic room temperature control and time of day control
electronic room temperature control and weekday control
Other control options (multiple responses possible)
room temperature control with presence detection
room temperature control with open window detection
with remote control option
with adaptive control of heating start
with operating time limiter
with black ball sensor
Manufacturer:
Vitramo GmbH | Zur Altenau 6 | 97941 Tauberbischofsheim | Germany
Tel: +49 (0)9341 85894-0 | Web: www.vitramo.com | E-Mail: info@vitramo.com
The heating element conforms to Regulation (EU) 2015/1188 (Ecodesign) if the room temperature control is achieved by
either VTX series devices or VTD-UP room thermostat.
Note:
1 In combination with window contacts of the VTX series.
2 In combination with remote control option of the VTX series.
1712205
VH03535 VH04848 VH06021 VH06060
P
in W
260
nom
P
in kW
0,3
nom
P
in kW
min
P
in kW
0,3
max,c
el
in kW
max
el
in kW
min
el
in kW
SB
www.vitramo.com
windows are monitored by the battery-operated VTX-FA or
VTX-FU window contacts and/or the remote control option is
used with the VTX-G gateway.
Room thermostat VTD-UP: The heating element is switched
directly by the room thermostat, which also measures the
room temperature. With the learning function activated, the
comfort temperature programmed in the weekly program is
reached at the set point in time, since the thermostat
controls the heating start adaptively.
550
220
800
0,6
0,3
0,8
N.A.
0,6
0,3
0,8
N.A.
N.A.
N.A.
VH06262 VH10050 VH12462
810
1210
1650
0,8
1,2
1,7
0,8
1,2
1,7
Value
No
No
No
No
No
Yes
No
Yes
1
Yes
2
Yes
No
No
31