Télécharger Imprimer la page

Honeywell Home CT230-GA Guide D'installation page 10

Publicité

Les langues disponibles

Les langues disponibles

Installation Guide
Installing the master thermostat
WARNING: Make sure all CT230 linked units are Off.
Connect the master thermostat to the nearest CT230 linked unit (see connection diagram on
page 7).
WARNING: Only one CT230 linked unit must be used to power the master thermostat.
Connect the floor sensor (included with the TH114-AF-12VDC & TH115-AF-12VDC
thermostat) to the master thermostat (no polarity, see connection diagram on page 7).
Position the sensor cable such that it does not come in contact with the floor heating wires. The
sensor must be centered between two floor heating wires for best temperature control.
Do NOT staple the sensor head (the plastic end) to the floor. Doing so might damage the sensor.
Any damage might not be noticeable during testing but can become apparent several days later.
Loosen the bottom screw and remove the faceplate from the wallplate. (The screw cannot be
completely removed.)
Install the wallplate on the wall using the provided screws and wall anchors.
Reinstall the faceplate on the wallplate.
Apply power to heating system and switch each CT230 linked unit and the master thermostat
to On.
Test the ground fault protection on each CT230 linked unit.
8

Publicité

loading

Ce manuel est également adapté pour:

Ct230-gb