Menu 66 – Continuous Timecode Chase
This parameter has been added to allow continuous off-speed synchronisation. To synchronise
off speed video syncs are not used and the timecode reader must be used as the positional
reference for the machine for the off speed machine. This parameter will default to zero !
IFACE General Menu's
Menu 67 – Machine Type
0= VTR
This parameter determines some initial settings depending on the machine type:
VTR with no digital audio tracks.
VTR
VTR with Digital Audio tracks.
Digital VTR
Audio Recorder.
ATR
A Stereo DAT with stereo record only.
DAT-1
Menu 68 – Position Request
0= LTC
1= VITC
Menu 69 – Pause/Stop Command
0= Normal
Some video machines will unlace if a STOP command is sent, for these machine it is possible
to send a Jog or Shuttle at Zero Velocity which will stop the VTR in a laced mode.
Menu 70 – Timecode Standard
0= Auto
Use Standard as reported by machine.
0= Auto
1= Use System Use Master Standard as defined by the Master machine or in Unit Setup.
Menu 71 – Auto Unlace
0= Enabled
This parameter allows you to disable the auto-unlace and rely on the machines unlace
function.
2017 CB Electronics
Clavier de contrôle TFT
Menu 66 – Continuous Timecode Chase
0= Off
Menu 67 – Machine Type
1= Digital VTR
Menu 68 – Position Request
2= LTC+VITC
Menu 69 – Pause/Stop Command
1= Stop
Menu 70 – Timecode Standard
Menu 71 – Auto Unlace
1= On
2= ATR
3= Timer-1
4= LTC+VITC+Timer
2= Jog@Zero
1= Use System
1= Disabled
3= DAT 1
3= Shuttle@Zero
Page : 30