the working mode again. (This condition is not available when the unit is under AUTO mode "J".)
REMOTE CONTROLLER
1. Slide the back cover to open and take off the isolating film on the batteries.
2. Put the batteries inside the slot, must be corresponding to the signs of "+" and "-" on the remote control.
3. For long time no use, take out the batteries.
4. To prevent environmental pollution, take out the used batteries and dispose safety and appropriately.
To operate the device, aim the remote controller (..) at the signal receptor. The remote controller will operate the device at distance 5 meters
when pointing at signal receptor of the device.
PROTECTIVE DEVICES
The protective device may trip and stop the appliance in the cases listed below:
1. at cooling mode: indoor air temperature is over 43°C (109°F)
2. at cooling mode: room temperature is below 15°C (59°F)
3. at dehumidifying mode: room temperature is below 15°C (59°F).
If the device runs in cooling "K" or dry "L" mode with door or window opened for a long time when relative humidity is above 80%, dew may
drip down from the outlet.
The protective device will work in the following cases:
1. Restarting the device immediately after stopping work or changing the selected mode while working, you must wait 3 minutes.
2. If the plug has been removed, after restarting the device will return to the original mode, TIMER ON and TIMER OFF - must be set again.
REMARK: there is condensing water recycling hidden within this unit. The condensing water is partly kept recycling between the condenser
and the water plate. When the water level rises to the upper level, the float switch and water full indicator (E4) lights on to remind draining
water. Please cut off the power supply, move the appliance to a suitable place, remove the drain plug, drain water completely. After the
drain, re-install the plug, or the appliance may leak and make your room wet.
If the appliance is placed in a position admitting drain water, you also can connect the drain hole to the drain port to drain the water. Drain
pipe is not added to kit, it should be: inner diameter 9mm , outer diameter 12mm, material: PVC.
Troubleshooting
1) Trouble: Do not work.
Analysis:
a) maybe the protector trip or fuse is blown, please wait for 3 minutes and start again, protector device may be preventing device from
working.
c) maybe batteries in the remote controller are exhausted.
d) maybe the plug is not properly plugged in.
2) Trouble: works for a short time only
Analysis:
a) if the set temperature is close to room temperature, you can lower the set temperature.
b) maybe air outlet is blocked by obstacle. Take the obstacle away.
3) Trouble: Works but not cools
Analysis:
a) maybe door or window are open.
b) maybe in close distance there is another appliance heat-working like heater or lamp, etc.
c) the air filter is dirty, please clean it.
d) air outlet or intake is blocked.
f) set temperature is too high.
8