Télécharger Imprimer la page

Leuze electronic AMS 300i Guide Rapide page 20

Système optique laser de mesure
Masquer les pouces Voir aussi pour AMS 300i:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
EN
Technical data
NOTICE
Technical data
 Additional specifications and notices for using the device can be found in the
technical description.
Operating voltage
Current consumption without/with heater
Light source
Laser class
Wavelength
Max. output power (peak)
Impulse duration
Measurement range
Accuracy
Traverse rate
Interface type
Switching inputs/outputs
Degree of protection
VDE safety class
Housing
Optics
Gewicht
Ambient temperature
Rel. air humidity (non-condensing)
Vibration
Noise
Shock
Electromagnetic compatibility
Conformity
Certifications
1) For UL applications: for use in class 2 circuits according to NEC only.
2) Protective Extra Low Voltage (PELV) - protective extra-low voltage.
3) Only with screwed-on M12 connectors or mounted caps.
4) This is a Class A product. In a domestic environment this product may cause radio
20
interference, in which case the operator may be required to take adequate measures.
1)
AMS 3xxi 40...
AMS 3xxi 120...
AMS 3xxi 200...
AMS 3xxi 300...
AMS 3xxi 40...
AMS 3xxi 120...
AMS 3xxi 200...
AMS 3xxi 300...
Operation without/
with heating
Storage
2)
18 ... 30VDC (PELV
250mA @24VDC /
laser
2 (in accordance with IEC 60825-1:2007),
see
1
655 nm
4mW
18μs
0.2 ... 40m
0.2 ... 120m
0.2 ... 200m
0.2 ... 300m
± 2mm
± 2mm
± 3mm
± 5mm
10m/s
see part number code
2, configurable
3)
IP 65
III
diecast zinc/aluminum
glass
approx. 2450g
-5°C ... +50°C / -30°C ... +50°C
-30°C ... +70°C
max. 90%
EN 60068-2-6
EN 60060-2-64
EN 60068-2-27
EN 61000-6-2, EN 61000-6-4
CE, CDRH
UL 60950-1, CSA C22.2 No. 60950-1
, Class 2)
500mA @24VDC
4)
1)

Publicité

loading