ALARM FUNCTION
The monitor can be connected to various alarms. It has an output port that sends the
G
alarm signal to another device on+5V TTL level for alarm setting time.
When the alarm goes off in QUAD or AUTO mode, the monitor automatically switches
G
to the screen of the camera where the alarm is generated and displays a blinking "A".
If the alarm breaks out at two or more places, the monitor switches to the QUAD
G
screen mode and displays a blinking A on the relevant screens.
Once the alarm is released, the monitor goes back to the previous mode automatically.
G
While the alarm continues, it cannot be reset. Remove the alarm factors.
G
In VCR or SETUP mode, the monitor switches to the alarm channel automatically.
A.RESET only resets the alarm time after the alarm factor is removed.
G
To disable the alarm completely (the alarm is not detected), set the alarm time to "OFF"
G
in the Setup Menu.
If you make the alarm off in the mode of VCR and SETUP mode, the system doesn't
G
go back to VCR or SETUP mode.
Alarm in the case of sub power off, the display is on.
G
*
AUDIO SYSTEM
This has One-way audio system. It is possible in quad mode or C1~C4 full screen
G
mode.
You can hear the sound from the selected camera without pressing any button.
G
(
OTHER FUNCTION
Volume doesn't work in setup mode, and OSD is displayed 1.5 second while volume is
G
controlled.
Please watch out at sub power mode, this is only for display off but electric power on
G
for system. No buttons or keys are not in active when sub power off.
If a camera is disconnected, the channel display is in freeze, and if it is connected
G
again, freeze will be off.
Power on set QUAD mode
G
MODE
PAGE A
PAGE B
PAGE A
PAGE A,B SWITCHING
C1~C4
C5~C8
one or more
none
none
one or more
none
none
one or more
one or more