Assembly and Operating Instructions
3) Tilt position
Warning
The reversing position must only be set up for use with blinds!
Note
This function enables the opening of the curtain from the lower end po-
sition to the desired tilt position. Both end positions have to be set prior
to setting the tilt position.
3a) Setting the tilt position
1. Adjust the curtain from the lower end position to the desired tilt position.
2. Now press and hold the STOP button; also press the UP button within 3 sec-
onds and keep both buttons pressed.
The curtain will "nod" to confirm.
The tilt position has been stored.
3b) Adjusting the curtain into the tilt position
1. Press the UP button twice within one second.
The curtain will move to the tilt position.
3c) Deleting the tilt position
1. Adjust the curtain to the tilt position.
2. Now press and hold the STOP button; also press the UP button within 3 sec-
onds and keep both buttons pressed.
The curtain will "nod" to confirm.
The tilt position has been deleted.
Note
If a reversing point is programmed, it will be executed after reaching
the intermediate position (double-tap DOWN). If no intermediate posi-
tion was programmed, the reversing point will be activated after the
end of the runtime.