Failed ignition
To turn the stove back on, reset the alarm by keeping the power button on the handheld (or on the electronic card) pressed until
the acoustic signal is heard and then switch on again.It is not necessary to remove any unburnt pellets inside the brazier. In fact, as
soon as the user reboots the stove, the system tries to ignite any fuel left in the brazier before starting the loading phase.
TROUBLESHOOTING
Alarm management
Alarms are indicated by an acoustic signal (if activated) and a message on the control panel. In case of an alarm the shutdown
procedure is automatically activated. Cancel the signal by pressing button P3 on the remote control or the emergency panel and
wait for the insert to reach OFF status. Eliminate the cause and restart the insert according to the normal procedure described in this
manual. Listed below are the alarms that can appear on the control panel, with the causes and cures:
Signalling
AL 1
-The stove does not start.
POWER
FAILURE
AL 2
-Occurs in case of a fume
FUME
temperature probe fault.
PROBE
-The
shutdown
activated.
AL 3
-Occurs if the fume probe detects
HOT FUMES
a fume temperature above 280°C.
-The
shutdown
activated.
AL 4
-Occurs when the fume exhaust
FAN FAIL
fan is faulty.
-The
shutdown
activated
AL 5
-No flame in ignition stage.
NO IGNITION
-The
shutdown
activated.
AL 6
-Brazier not fed with pellets.
NO PELLETS
AL 7
--Occurs in case of cutting in of
THERMAL
auger duct temperature or heating
SAF
chamber water temperature safety
thermostat.
-The system is stopped.
AL 8
-In the work stage the stove detects
NO NEG
a pressure below the vacuum
PRESS
switch setting threshold.
-The system is stopped.
AL 9
-Appears when the combustion air
INSUFF
flow is below a certain threshold.
DRAUGHT
AL E
-Occurs when the water pressure
WATER
does not come within the values for
PRESSURE
correct operation.
-The system is stopped.
Use and maintenance manual HRB 150 - HRB 200
ALARMS - MESSAGES
Fault
-No power during the lighting stage
-Faulty probe
-The probe is disconnected from the
procedure
is
board.
-Faulty tangential fan.
-No power to tangential fan.
procedure
is
-Too many pellets
-The fume fan is blocked.
-Faulty speed control sensor.
procedure
is
-No power to fume fan.
-The pellet hopper is empty.
procedure
is
-The electrical element is faulty, dirty
or not correctly positioned.
-Pellet load setting incorrect. .
-The pellet hopper is empty.
-The pellet feed gearmotor has to
adjust.
-The gearmotor does not feed pellets.
-The safety thermostat has detected
a temperature above the setting
threshold due to overheating of the
bottom part of the hopper or the
heating chamber water, blocking
gearmotor operation.
-The combustion chamber is dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are open-
stuck.
-Faulty vacuum switch.
-The combustion chamber is dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The
overpressure
openstuck.
-Faulty air flow meter.
-Occurs when the pressure transducer
on the water circuit detects a pressure
below 0,6 bar or above the fixed limits.
Possible causes
-Turn the stove OFF by pressing the
button P4 and repeat the lighting
procedure.
-Other reinstatement operations must
be carried out by a service centre.
-Reinstatement operations must be
carried out by a service centre.
-Adjust the pellet flow.
-Other reinstatement operations must
be carried out by a service centre
-Reinstatement operations must be
carried out by a service centre.
-Check pellets in hopper.
-Check the lighting procedures.
-Other reinstatement operations must
be carried out by a service centre.
-Check pellets in hopper.
-Adjust the pellet flow
-Other reinstatement operations must
be carried out by a service centre.
-Check
overheating.
-Reset the relevant safety thermostat
by pressing the reset button.
-Check cleanness of the fume duct and
combustion chamber.
-Check hermetic closing of the door.
-Check closing of the overpressure
valves.
-Other reinstatement operations must
be carried out by a service centre.
-Check cleanness of the fume duct and
combustion chamber.
-Check hermetic closing of the door.
valves
are
-Check closing of the overpressure
valves.
-Other reinstatement operations must
be carried out by a service centre.
-Check the cause of the problem,
restoring the circuit pressure by bringing
it to the normal operating value.
Cures
the
cause
of
excessive