Watts Electronics Vision WiFi Manuel D'utilisateur Et D'installation page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
House creation
A
See house creation section.
Radio pairing.
B
See radio pairing section.
Delete a device:
C
Select device type and then the device.
Delete all devices:
D
All devices installed in the system will be deleted (rooms
will be maintained).
Identify a device
E
To identify a device of the installation,
a Device"
a- To put the menu in reception mode.
b- To access to the device parameters.
Process:
- Press on 'a' to make the Central listening
- Press on the device receiver and wait a few seconds until radio
communication frame is transmitted.
Note: ID-number is displayed on the screen, please repeat to be
sure to have the same ID.
- Long press on
to change device parameters (name,
power ...).
Antifreeze setpoint:
F
You can set the antifreeze setpoint as reference for the whole
installation.
Heating setting:
G
You can fix setpoint limitations (min/max) per zone and the offset
assigned to devices working in floor sensor regulation
Heating/cooling settings:
H
You can set the installation in heating mode, in cooling mode or
in manual mode. If you set the device in manual mode, the
icon appears on the main menu.
J
K
L
.
go to Menu,then "Identify
b
a
I
WIFI settings:
To set the WIFI configurations (SSID/Protected Access Key
Type/ Password). You can do it manually or scan the active
networks.
Configuration requesting a registration on a web page is not
supported.
WIFI Status:
0/2 : Central unit not connected to the wifi router and server
1/2 : Central unit connected to the Wifi router
2/2: Central unit connected to the wifi router and to the server
(Pairing of the central to an account is required)
n.b.: The connection to Internet is recommended with Certified
WiFi routers (http://www.wi-fi.org/certification).
n.b.: Automatic pairing time to WiFi router with WEP key: 3-4
min, with WPA2 key: 1 min.
n.b.: For the network scan, Repeat at least twice the operation if
your desired WiFi network is not displayed. If your desired WiFi
network is still not displayed, enter the WiFi settings manually
General factory default:
J
To reset the system with the factory values, but the software
version will remain the same.
Update Firmware:
K
To update the software, with the SD-card. The system is
qualified to work with SD-cards less than or equal to 16GB.
Select
to proceed.
Please wait the end of the update procedure (The Wifi icon
should be available for the Wifi central unit) before removing the
microSD from the central unit.
The SW and the procedure to update the central unit is available
on www.wattswater.eu.
L
Cloning:
The menu allows to transfert a configuration from central 1 to
central 2. If you change the central, you do not have to
reconfigure your system.
Put update.bin file on SD card (Special software for cloning
available on www.wattswater.eu.
Insert the SD card in central 1 and make an update firmware
Insert the same SD card in central 2 and launch the cloning.
After the cloning, you need to reconfigure the Wifi and the
langage.
Displosal and recycling information
Correct disposal of this product. This marking shown on
the products indicates that it should not be disposed with other
household waste at the end of its worlking life.
Disposal of waste batteries: This product contain batteries. If so,
use the separate collection for battery recycling. Do not ut them
with other household waste.
This device is suitable for use by children 8 years of age or older,
and for persons with reduced physical, sensory or mental
abilities or lack of experience or knowledge, if they are properly
supervised, or if instructions on the safe use of the device have
been given to them and the risks involved have been addressed.
Children should not play with the device. Cleaning and
maintenance by the user should not be performed by unattended
children.
9

Publicité

Table des Matières
loading

Table des Matières