User Menus; 24-Hour Overview; Target Temperature; Minimum Ventilation - MS Schippers MS Fan Controller Touch Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3 User menus

This chapter discusses all settings in the user menu.

3.1 24-hour overview

This opens a 24-hour temperature and ventilation graph. Different graphs can be selected with the icons on
the right side of the graph. The graph can be closed by pressing the 'X' icon in the upper right corner of the
graph.
Yesterday's measurements are shown with a thin orange graph line. A thicker blue graph line shows today's
measurements to the present time.

3.2 Target temperature

Input range: 0.0°C - 50.0°C [factory value: 20°C]
Here you can set the desired temperature for the department.

3.3 Minimum ventilation

Input range: 0% - 100% [factory value: 10%]
Here you can set the desired minimum ventilation. This is the ventilation rate when the room temperature is
equal to or lower than the set temperature.

3.4 Maximum ventilation

Input range: 5% - 100% [factory value: 100%]
Here you can set the desired maximum ventilation. This is the ventilation rate when the room temperature
has reached the end of the bandwidth.
MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING
EN - MS Fancontroller Touch
24 uur grafiek
Streef-
temperatuur
Minimum
ventilatie
Maximum
ventilatie
Open grafiek