1) If the range hood or halogen light does not
operate after installation:
2) The range hood vibrates when the blower is on:
3) The blower or fan seems weak:
4) The lights work but the blower is not spinning at
all, is stuck or is rattling.
5)
The hood is not venting out properly:
:
Check if the range hood has been plugged
•
in, make sure that all power has been
turned back ON, fused not blown and all
electrical wiring are properly connected.
• The range hood might not have been
secured properly on to the ceiling or wall.
Check that the duct sized used is at least
•
6" or 3-1/4 x 10". Range hood WILL
NOT function efficiently with insufficient
duct size. For example: 7" duct over 6"
hole and loosely secured.
• Check if duct is clogged or if damper unit
(half-circular flapper) is not installed
correctly or opening properly. A tight
mesh on a side wall cap unit might also
cause restriction to the air flow.
• The blower might
scraping the bottom due to shipping
damage. Please contact us immediately.
Make sure the distance between the
•
stove top and the
is within 24" and 30" in distance; with
minimum 30" for gaz stove top.
Reduce the number of elbows and
•
length of duct work. Check if all joints
are properly connected, sealed, and
taped.
be jammed or
bottom of the hood