Volume control: Continue to turn the knob [6] clockwise to adjust the volume to the desired
level.
•
Channel selection: Press the up/down keys on the microphone to change the channel
number.
•
Squelch level control: Press the [SQ] key briefly. The current squelch level will appear on
the screen. Use the up/down keys to select the desired SQ level (from 0.1 to 2.8) or OF to
disable the function.
0.F = Squelch off
0.1 = Lowest Squelch level
2.8 = Highest Squelch level
Note: Higher SQ level require a stronger signal to open the speaker and hear the spo-kesman.
•
ASQ control: Long press the [SQ] key to activate the ASQ function. The "AQ" icon and the
current ASQ level will appear on the screen. Use the up/down keys to select the desired ASQ
level (from A.1 to A.9). Press the [SQ] key long to deactivate the ASQ function.
A.1 = lowest level
A.9 = highest level
Notes:
Higher DS level require a stronger signal to open the speaker and hear the spokesman.
For automated Squelch, we recommend level A.2 (or A.3 for louder areas).
Modulation type: Briefly press the [A/F] key to change between AM and FM. The selected
•
modulation will appear on the screen.
Note: Before modifying the modulation, check the selected standard.
•
RF Gain control: Press the [RFG] key briefly. The "R" icon will appear on the screen and the
current RF gain level will blink. Use the up/down keys to change the level (06, 12, 18, 24, 30,
36, 42, 48, 54).
Note: We recommend RFG function disabled (or level 06 for louder areas).
•
Emergency channel: Press the [EMG] key briefly. The channel number 09 blinks on the
screen. Press again, the channel number will blink 19 on the screen. Press the third time to
return to the normal channel.
•
Key Lock: Press long the [EMG] key. The "LC" icon will appear on the screen. Key lock
function is active. Press the [EMG] key again, OF will appear on the screen. The key lock
function is disabled.
•
Scan function: Press long the [A/F] key to start channel scanning. The "SC" icon appears on
the screen. Use the up/down keys to change the direction of the scan. Press the [A/F] key or
the PTT key on the microphone again to deactivate the scan function.
CHANGING THE CB-STANDARD
To change the standard you are using the CB radio in, do the following:
•
Press and hold the [A/F] - A/F key while turning on the radio
•
Press the up/down keys to select the desired standard
•
Close and restart the radio. Immediately after turning on, the current standard will be displayed
for a second.
FREQUENCY BAND CHART:
Standard
EU
CE
UK
Channel
Europa 40FM/40AM 4W
CEPT 40 FM 4W
Anglia 40 FM 4W
Frequency
26.965-27.405MHZ
26.965-27.405MHZ
27.60125-27.99125MHZ
5