Installation instructions
1. POSITION
It is recommended to place the pump of the counter-current in a way that the connection between the pump and the fitting parts
is as short as possible. In any case you have to ensure that the pump is installed in a manner that the axle is in a horizontal posi-
tion. Changing the place of the pump is possible due to construction reasons. We recommend not to go beyond 5 m maximum
distance for avoiding any higher flow reduction on the suction side. While placing the installation please ensure that the pipes
in that maximum area are passed without breakes and in a horizontal way. If there are larger distances, you have to increase the
diametre of the pipes. The place of the pump has to be an area, where the ambient temperature does not exeed 40°C. Place the
pump under the water level because the pump does not suck itself. The pump and the locking parts have to be accessible any
time. Ventilation and drainage as well as floor drain have to be provided in the pump shaft.
2. INSTALLATION
The equipment is supplied as standard with all nessary fittings. The wall pack is suitable for 240 mm concrete wall. The wall pack
should be mounted in a way that the centre of the nozzle is between 200 and 250 mm below water level and is not placed less
than 1,5 m from the side wall.
After finishing of the construction and cleaning of the fitting parts, you may assemble the unit. The air and piezo connection of
the fitting have to be connected with the transitions in the wall pack. When pushing the fitting in, the cables must not be dam-
aged. Fix the fitting by using the delivered screws on the wall pack.
Now, the non-return-valve in the pump shaft has to be connected to the air hose. The non-return-valve has to be installed above
water level. The piezo cable is to be lead above water-level and has to be connected to the control box. The connection between
the pump and the wall kit is made according to the drawing and part list.
3. STARTING UP
Ensure that the pool is full of water before starting up the pump. Avoid any dry run of the pump.
1.
Open both valves and turn on the installation by using the piezo switch.
2.
Check the air injection.
3.
Hose and tube connections have to be checked on leakage during the working process. Due to temperature
differences tighting of the connections can get neccessary. (Check the system on leakage by reducing the installa-
tion as much as possible).
4. OPERATING
It is switched on and off by using the piezo switch. The nozzle can be adjusted in the direction. Adjust the current speed in a
way that the swimmer can swim against the full jet.
5. HIBERNATION
The pump has to be empty. Close both valves and open the screw on the housing of the pump for emptying.
During down times the circuit should never be operated without voltage (except for maintenance work) due to danger of con-
densation forming. Piezo button during winter: For safety reasons the piezo button is to be deactivated using the switch on the
control box/cabinet, i.e. set to winter operation.
6. POSSIBLE PROBLEMS AND SOLUTIONS
6-1.
Installation does not produce sufficient power: Pump is turning in the wrong direction. Water level is too low.
Pump sucks in air. Valve is not completly open. Suction pipe leaks. Pump is clogged (with leaves for instance).
If the causes can not be identified, inform the service responsible.
6-2. Pump can not be switched on: Check the cable between the piezo switch and the control and check the configura-
tion of the connection of the control and the switch for summer/winter operation. Possibly reset the motor protection relay.
6-3. Relay for motor protection switches off: Relay for motor protection is not adjusted correctly.
Rated current and local situations have to be consistent with the adjustment of the relay for motor protection.
Pump is overheated. Cool down the motor, reset motor protection relay and start it again.
Phase failed - check the fuses.
6-4. Residual Current Device (RCD) switches off: The equipment has to be checked by an electrician.
Stand 12/2014