MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
D
B
ual
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.
Lamp Modes
There are three lamp modes (light turn-on effects) avail-
able when motion is detected:
• SECURITY ("NORMAL") - Light instantly comes
on.
• BULBSAVER ("SOFT") - Light starts dim and grad-
ually increases to full brightness. Light gradually
dims to half-bright, pauses, and then continues dim-
ming to off when motion is no longer detected and
after selected ON-TIME.
• ALERTFLASH ("FLASH") - Light flashes on then
off twice before turning on full brightness.
1 Second OFF
then...
... back on.
Move ON-TIME Switch to
1, 5, or 20 minutes
Flip light switch off
for one second then
back on*
Timer
®
rite
INSTALLATION
For easy installation, select an existing light with a wall
switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m)
above the ground. NOTE: If fixture is mounted higher than
8 ft. (2.4 m), aiming the sensor down will reduce coverage
distance.
Wall Mount
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
❒ Swing the sensor head towards the clamp screw
joint.
Clamp Screw
❒ Then rotate the sensor head clockwise 180° so the
controls face down.
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
2
Eave Mount
Controls
Controls
Controls