Floor load capacity
Make sure that the load capacity of the supporting
construction is sufficient to carry the weight of the
, before the heating unit is installed.
entire unit
Combustion air
Being the user of the stove you must take care of a
sufficient combustion air supply. Sealed-up windows
and doors may not allow a sufficient combustion air
supply or disturb the draught behaviour of your stove.
Please ensure the additional supply of fresh
combustion air if necessary. For details please
consult your specialist retailer.
3. CORRECT OPERATION OF YOUR STOVE
Approved fuels
Dry, well cured and natural wood (hardwood
preferred), wood briquettes.
Maximum amount of fuel
Maximum amount of fuel to be added: appr. 1,6 kg
wood or appr. 1,6 kg wood briquettes
amounts of fuel can lead to overheating and thus
damage the stove.
Clean burning
The wood must be dry (relative wood moisture
< 15%) and untreated. The right amount of wood
must be burned in order to ensure a clean fire that
releases only small amounts of emissions.
Making a fire
Prepare everything you need for starting the firesoft
wood chips, igniter materials (such as Austroflamm
lighter), wood. Figure 1 provides a good overview of
the quantity of the materials you will need.
Open the air all the way. See figure 2.
Open the stove door.
Put ignition aid on the floor of the firebox.
Lay soft wood chips onto the paper.
Lay one or two logs of wood on the wood chips.
5
Stove pipe connection
For your own safety stringent laws apply for
connecting the stove pipes to the chimney. Your
professional dealer or distributor knows these laws.
Please have your certified retailer carry out the
connection of your stove.
.
Light the ignition aid. Close the firebox door.
. Larger
As soon as the wood logs are burning well, you
can regulate the heating capacity with the air
slider. (slider set to the maximum ("AUF") setting
produces maximum heat – see figure 2.)
When adding wood to the fire, follow the same
procedure as when igniting the fire: Open
secondary air, carefully open firebox door, lay
wood on the fire, close the firebox door.
Wait until the added wood catches fire and is
burning. Subsequently regulate the fire with the
secondary air supply.
Figure 3: Igniting the Fire