ENGLISH
1) INSTALLATION INSTRUCTIONS
2) P1000 XL Flush cock ND20 - G3/4" EN 12541 compliant
3) PRECAUTIONS FOR USE (The product guarantee depends on the respect for these rules)
INSTALLATION and START UP
For products delivered with filters, these must be installed in accordance with the instructions.
Before commissioning any of our valves, it is essential to carefully drain
the pipes that can damage the mechanisms or water passages (PRESTO® heads that can be dismantled from front).
Recommended operating pressure according to NF EN 816: 1 to 5 bars.
CLEANING
The chrome-plated coating of PRESTO® valves must be cleaned only with soapy water.
Abrasive, acid, alkaline or ammonia-based household products are prohibited.
4) Part no. 14210 - P1000 XL Flush cock Class I
Part no. 14201 - P1000 XL Flush cock Class II
Part no. 14200 - P1000 XL Flush cock Class II without shut-off valve
(Note: The flush cocks must be equipped with an individual shut-off valve)
Technical data:
- G3/4" Male feed - Poli-chrome plated brass body
- 1/4 turn stop cock
- Automatic flow limiter.
- Adjustable supply volume: 6 to 9l. (Supplied set to 6l)
- Flexible push button with 3 angular positions
- Outlet connector for 28x1 tube (part no. 47270).
5) Shut-off valve
6) Flush tube Height 500 mm minimum
7) Installation
8) Bleed the installation before installing the valve
9) Wall-mounted supply with shut-off valve Part no. 14201 and 14210
10) Protection supplied to be removed after installation
11) Left or right transverse supply
With shut-off valve Part no. 14201 and 14210
12) Without shut-off valve Part no. 14200
13) Installation of the flush tube
14) Direction of the air intake ring towards the wall
15) Knee bend Ø 28 x 1 Part no. 47270
16) Adjustment of the supply volume (set at 6l) (1.2 < P < 4 bars)
17) Flow curve
18) Volume (litres)
19) Flow rate (l/s)
20) Number of turns
21) Pressure (bar)
22) Special hex head key 3 not supplied Part no. 90801
23) Volume
24) In the event of an anomaly, remove the timer cartridge and rinse in clean water
25) In order to benefit from the acoustic grading of P1000XL, never use the shut-off valve for flow regulation.
It must be mostly kept open
26) Dismantling the valve
27) Spares bags for P1000 XL Class II - Timer cartridge – Part no. 01270
28) P1000 XL discharge Part no. 90825
29) Replacing the cartridge
30) Cartridge + seals Part no. 01270
31) Foolproof location of the cartridge in the body
32) For the adjustment of the volume see chapter "Adjustment of the supply volume"
33) Foolproof location of the seal in the cartridge
34) This document is not contractual; we reserve the right to modify the characteristics of our products without notice.
35) PATENTED and REGISTERED MODELS
6
- Hydraulic discharge P1000 XL – Part no. 90930 90825