USER'S MANUAL
ELECTRONIC PUMP CONTROLLER
PRESFLO
is a device that
®
starts and stops the pump to
which it is fi tted, thus replacing
traditional pressure switch /
surge tank systems.
The pump is started when, as
a tap is turned on, the pressure
within the system drops below
the "start-up pressure" (Pm),
and is stopped when the fl ow
Technical specifi cations
- Voltage: ~ 230 V / ~ 115 V
- Frequency: 50-60 Hz
- Current: 16A max for 3 sec .
- Protection grade: IP 65
- Start-up pressure ( Pm ): 1÷5 Bar (15-70 psi)
- Shut-off fl ow rate ( Qa ): 2 litres/min (0,5 gpm)
- Connections: 1"M BSP / 1"M NPT
- Operating pressure: 8 bar (120 psi)
- Bursting pressure: 24 bar (350 psi)
- Weight: 1600 g
- Protection against: dry running
( automatic restart),
repeated start-ups, overcurrents
- Max liquid temperature: 55°C
Before installing, the product, check
that the RATINGS correspond with those
required.
Losses
0
Water accumulator pressure.
Should be infl ated to a value 0,5 bar lower than
the running pressure.
Operating conditions
A. Compatible/non compa-
tible fl uids
PRESFLO
is suitable for use
®
with clean water and chemical-
ly non-aggressive liquids. If the
fl uid contains impurities, a fi lter
should be fi tted upstream.
B. Environmental conditions
PRESFLO
should not be used
®
where there is the risk of an
explosion. The temperature
of the location should range
between 0°C and 40°C, and
the humidity should not exceed
90%.
C. Power supply
Make sure that the variation
rate required is zero or less
than the "shut-off fl ow rate"
(Qa).
The electronics of PRESFLO
protects the pump against
abnormal running conditions
such as dry running, repeated
start-ups due to leaks in the
system or overcurrents.
CODE:
V00103101
V / Hz:
~230 / 50-60
16 A
I max:
SN 1506003
50
100
150
Working area
Pm
Qa
Shut-off fl ow rate
in the power supply is never
more or less than 10 % of the
RATING value.
Higher values may cause
®
Safety regulations
Before installing or using
PRESFLO
, read this manual
®
carefully and thoroughly.
The pump should be installed
and serviced by qualifi ed per-
sonnel, responsible for making
the hydraulic and electrical
connections in compliance with
the relevant regulations.
PEDROLLO S.p.A. shall not
be held liable for any damage
relating to, or resulting from, an
B
improper use of the product,
or for any damage relating to,
or resulting from, servicing or
repairs carried out by unqua-
lifi ed personnel and/or with
non-OEM spare parts.
The warranty, which is valid
for 24 months from the date
of purchase, will no longer be
applicable should the product
suffer damage as a conse-
200 l/min
quence of the use of non-OEM
spare parts, tampering or
improper use.
When starting the installation,
check the following:
To set the running pres-
sure (Pm) and the max.
motor current (I max.), see
Confi guration paragraph.
Manufacturer's
settings
Start-up pressure
2 l/min (0,5 gpm)
damage to the electronic
components.
PRESFLO
can only be used
®
with single-phase pumps.
IT
EN
IT
EN
ES
- the power supply is switched
off.
- the power lines can withstand
the maximum current.
- the cable bushings and circuit
board cover have been properly
assembled and secured ( see
Electrical Connections ).
- the power supply is fi tted with
regulation earthing and safety
devices.
When servicing the product,
check the following:
- the system is not pressurised
(turn a tap on)
- the power supply is switched
off.
Emergency Stop
When in use, the pump can
be stopped in the event of an
emergency:
press STOP/RESTART.
PRESFLO
®
SERVICE.
5,0 bar
For no reason, disassemble
(75 psi)
the water accumulator with the
system pressurized.
2,0 bar
(30 psi)
1,0 bar
(15 psi)
Flow rate
ES
FR DE
FR
RU
RU
is put OUT OF
Water accumulator
Cover
12039908PFM
02-21