CONTROLS AND INDICATORS
POWER Button (RED) (1)
The power button switches the power on and
off.
LCD Display (2)
The LCD display gives status, automatic count,
total count, software version, field strength, user
instructions and fault messages.
Media Entrance Door (3)
The intimus 9000 media degausser operates
automatically when media is inserted into the
Media Entrance Door.
3
Charge Error
"Charge Error" is displayed on the LCD
screen. This error indicates that the degausser
failed to charge to the determined power level
necessary to successfully erase the media in the
degaussing chamber.
Note: The media will stay in the degaussing
chamber until a successful erase sequence has
been completed.
Action: Turn off the degausser for one minute and
restart. (Turning off the power to the degausser
will clear the error.) If the error repeats, have
the power mains checked and also check the
degausser to make sure the power setting is set
to match the power mains. If error persists, call
customer support.
Gauss Error
The LCD displays "Gauss Error". This error
indicates the erasing field may not have been
adequate to effectively erase the media in the
degaussing chamber. Media will not be ejected.
6
OPERATION
OPERATION
The intimus 9000 operation is automatically
completed in one cycle or when the media has
been released down the exit chute.
Note: As a safeguard, the media will stay in the
degaussing chamber until a successful erase
sequence has been completed.
DEGAUSSING INSTRUCTIONS
Automatic Degaussing
Sensors built into the Media Entrance Door
(3) sense that a hard drive has been inserted.
The act of depositing media through the Media
Entrance
Door
degaussing process.
1
MALFUNCTIONS
Action: Turn off the degausser for approximately
one minute. Turning off the power to the
degausser will clear the error. Turn the degausser
back on. To initiate the degauss cycle with media
already in the degaussing chamber, push the
Media Entrance Door open and let it close. The
media in the degaussing chamber will be erased
and only released with a successful degauss.
has finished. If error persists, call customer
support.
Door Open Error
The LCD displays "Door Open". This error
indicates that the Media Entrance Door is not
completely closed. The degausser checks to see
if the Media Entrance Door is closed just before
the media is to be erased.
Once the door is closed, the degausser will
automatically continue the erase function.
Action: Check Media Entrance Door for
obstructions.
Translation of the Original Operation Manual
Übersetzung der Originalbetriebsanleitung
automatically
initiates
the
2
000061
Powering Up
Press the POWER button (1) ON. The degausser
will go in to its power up sequence. The LCD
Display (2) will show start up messages including
firmware version and total count ending with
"Insert Media Session = 0". Automatic
Degaussing has now started.
Automatic Degaussing Steps
Step 1: Press power button (1) ON.
Step 2: Wait for the LCD (2) to display "Insert
Media".
Step 3: Insert media through the Media En-
trance Door (3).
Step 4: Remove degaussed media from Media
Slide.
Step 5: Repeat Steps 2,3 & 4.
Degaussing Instructions for DLT Media.
The Intimus 9000 allows DLT media to be
erased in their plastic protective cases. Simply
follow the degaussing instructions above for
complete erasure.
Note: For DLT media that is to be re-used.
Although the data is completely degaussed in
one operation, a second pass rotated at 90 de-
grees is required to smooth out any magnetic
fluctuation.
Note: If the second pass is not completed, the
tape drive may eject the tape from the tape drive
and indicate that the tape needs cleaning. The
second pass at 90 degrees will correct this con-
dition. If you have any questions, please contact
your dealer.
Overheat Error
The LCD displays "Overheat". This error
indicates the internal temperature has risen to a
level that may be harmful to the degausser.
Action: When the degausser indicates an
overheat error, it will inhibit any further operation
until the degausser returns to an acceptable
temperature. Leave the degausser powered
on as the chassis fan will help reduce the heat
inside the degausser. When the temperature is
low enough, the degausser will return to normal
operation. If this error persists, call customer
support.
EJECTING MEDIA AFTER AN ERROR
To retrieve media that has remained in the
degaussing chamber due to an error:
Step 1: Turn the degausser OFF.
Step 2: Turn the degausser ON. (by pressing
the POWER button).