2. Equipped with a large power low noise electric motor and centrifugal leaf, it produces strong suction,
low noise, non stick grease filter and easy to clean.
3. With the isolated low voltage circuit board control, 12vDC input, the lights are therefore safer.
4. Special wind tunnel construction and oil collector design, free dirt will be absorbed in a second.
(4). INSTALLATION
4.1 For optimum performance the extractor hood should be installed
approximately 65-75 cm above the ho
4.2 The hood is supplied with screws and rawlplugs which are suitable for
most types of wall and ceiling. However it is advisable to consult a
qualified technician to ensure that the materials are right for your wall or
ceiling. The wall or ceiling must be strong enough to support the weight of
the hood.
4.3 Electrical connection: The mains current must match the current stated
on the characteristics label situated inside the Hood. If the plug included is correct, connect the hood to a
socket which meets safety requirements in an accessible location. If the hood includes a direct mains
connection, use a double pole switch with a minimum distance between open contacts of 3 mm (accessible).
4.4 Study Figure A.
4.5 For wall installation drill three 8 mm holes every 100 mm in line with the hook of the hood.
4.6 Insert the rawlplugs.
4.7 Fix the hook to the wall and install the plate.
4.8 Fix the one-way valve with the screws supplied, add the reductor and the soot tube, and draw it
outwards (see Figure B).
4.9 Place on the wall (Figure C).
4.10 Calculate the final height of the U-shaped section and pull the inside of the U-shaped section up to the
correct height.
4.11 Secure the template in the lower tube using the screws supplied to mark out and drill two 8 mm holes in
the wall (Figure D).
4.12 Finally, drill two 8 mm holes in a suitable p lace in line with the second plate (Figure E) and tighten the
two screws.
English
Spanish
Hook
Gancho
Soot tube
Conducto para el hollín
Valve
Válvula
U-shaped section
Sección en forma de U
Plate
Placa
Drilling template
Plantilla para taladrar
THE CLASS 1 HOOD MUST BE EARTHED
The connection should be made as follows;
BROWN
BLUE
YELLOW/GREEN
THE CLASS 2 HOOD MUST NOT BE EARTHED
Second class hoods with the characteristics label containing the double square symbol.
The connection should be made as follows;
BROWN
BLUE
=
L (live)
=
N (neutral)
=
Earth
=
L (live)
=
N (neutral)
13