appliances. Please dispose your old appli-
ances using appropriate collection sys-
tems.
Notes about the ingredients (REACH)
You will find current information about the
ingredients at:
www.kaercher.com/REACH
Nozzles packet
You need to use the matching high pres-
sure nozzles to ensure that your high pres-
sure cleaner works properly.
Note:
The required packets of nozzles have been
adjusted to suit the corresponding high
pressure cleaners and must therefore be
ordered separately.
Figure 1, see cover page
1 Nozzle size (example)
Read the nozzle size from the type
plate of the high-pressure cleaner.
Select the nozzle package that is suita-
ble for the high-pressure cleaner from
the following table.
Nozzle size
Nozzle pack-
high-pres-
age
sure cleaner
036...040
2.642-431.0 2x10 + 20
041...045
2.642-432.0 2x11 + 23
046...050
2.642-433.0 2x12 + 26
051...080
2.642-982.0 2x20 + 40
081...100
2.643-769.0 2x30 + 40
101...125
2.643-768.0 2x38 + 50
Assemble nozzle packet
Figure 2, see cover page
1 O ring
2 Rotation arm
3 Nozzle
4 Union joint
Inser the O ring in the nut of the rotation
arm.
Place the nozzle on it.
Slightly fasten the nozzle with the Union
joint.
Nozzle size
nozzle pack-
age
– 2
EN
Note:
The exit jet must be directed parallel to the
rotation arm.
Figure 3, see cover page
Adjust the wrench area of the nozzle
(width 10) so that it is parallel to the ro-
tation arm.
Tighten the Union joint (width 22) using
a wrench.
Repeat the process on the second rota-
tion arm.
Note:
Do not attach the nozzles for the surface
cleaner to the spray lance of the high-pres-
sure cleaner.
Figure 4, see cover page
1 Injector nozzle
2 Wrench
Screw the injector nozzle into the injec-
tor using the wrench and tighten it fin-
gertight (8 Nm).
The wrench is included with the nozzle
set.
Operation
Figure 5, see cover page
1 Trigger gun with control knob
2 Trigger gun without control knob
3 Nipple, short
4 Nipple, long
In delivery condition, the short nipple is in-
stalled on the device for use on a trigger
gun with a control knob.
For use with a trigger gun without a control
knob, the short nipple must be unscrewed
and replaced by the enclosed long nipple.
Grease the O-rings of the nipple before in-
stallation.
Figure 6, see cover page
Connect the trigger gun of the high-
pressure cleaner to the surface cleaner
and hand-tighten it.
Tighten using a wrench (27 mm) if
needed.
CAUTION
A strong wastewater jet will emerge from
the hose connection. Do not use the sur-
face cleaner without a hose.
7