Product Description; Approvals And Markings; Function - DOLD SAFEMASTER STS RX11A Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Technique
SAFEMASTER STS
Safety Switch- and Key Interlock System
Basic Unit RX11A, RX11BM and RXK11M
RX11A
RX11BM
Presentation in the deactivated state:
1st key inserted; 2nd key and actuator removed

Product Description

Mechanical guard locking with separate actuator and electrical monitoring
of the position of the actuator or key 1 and the forced extraction of key 2.
To secure separating guards such as safety gates and oods in machine
and plant engineering.
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
STS-System Benefits
• EU-Test certificate according to the directive 2006/42/EG, annex IX
• For safety applications up to PLe / Cat. 4 acc. to DIN EN ISO 13849-1
• Modular and expandable system
• Rugged stainless steel design
• Wireless mechanical safeguarding
• Combines the benefits of safety switch, solenoid locking and
key transfer in a single system
• Easy installation through comprehensive accessories
• Protection against lock-in
• Coding level low, medium, high according to DIN EN ISO 14119:2014-03
Features
• The units are particularly suitable for applications with:
• Full body access (lock-in danger)
• Forced key removal
• Several secured entries
• Extremely rugged ambient conditions
• Required feed back signal of the key or actuator
• Required access rights
RXK11M

Approvals and Markings

Function

Mechanical solenoid locking for separating guards with forced key entry and
forced key removal as well as electrical monitoring function.
With the RX11A version, actuators can be inserted into the actuator module
from the side or from above. must be introduced. The coding level of the
associated actuator according to EN ISO 14119:2013 is low.
The RX11BM version offers increased stability of the actuator module. It is
also available in accordance with EN ISO 14119:2013 with actuators for
low and medium coding levels.
The second key can be used as part of a key transfer system or as a
personal key, i.e. as protection against confinement and unexpected restart.
Multiple keys make it possible to operate several units in the system or to
protect several people. For this purpose, the RX11BM unit can also be
extended above the actuator module with additional key modules. By using
personal keys, an escape release (ISO TS19837:2018) can normally be
dispensed with.
Like the RX11BM, the RXK11M version offers increased stability of the
actuator module. It is also available in accordance with EN ISO 14119:2013
with low and medium coding level. The second key can be used as part of
a key transfer system or as a personal key, i.e. as protection against con-
finement (ISO TS 19837).
Optionally, all variants can be equipped with padlock modules. These units
can be connected to the SAFEMASTER STS option module, which includes
command functions and is designed for wiring cross-sections up to 1.5mm