TOOLS NEEDED FOR INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1 1/4" Wood Drill Bit
• Scissors
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS SUPPLIED FOR INSTALLATION
• 1 Hardware Package
• 1 Literature Package
PARTS NEEDED FOR INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• 1 Wall or Roof Cap
• All Metal Ductwork
OPTIONAL ACCESSORIES AVAILABLE
• Glass Kit
20" deep by 36" wide glass "canopy" that mounts
to the bottom of the Cylindra
Part # GLSCYLN
• Charcoal Filter Kit
For non-vented installations only
* it is highly recommended that professional style
cooking always be vented to the outside
part #620000041
• CFM reduction kit
For make up air environments, converts the Cfm
of this hood to under 300 cfm
part #CFMRED
• Remote Control
Use a wireless remote to operate the rangehood
part #REMCTRL
WARNING
!
PERSONAL INJURY HAZARD
Because of the weight and size of the rangehood
canopy, two or more people are needed to move
and safely install the rangehood canopy.
Failure to properly lift rangehood could result in
damage to the product or personal injury.
PLAN THE INSTALLATION
This rangehood can be installed as either ducted or ductless. When ducting
outside, the blower can be vented through the wall or ceiling. To vent through
a wall, a 90° elbow is used. When installed ductless, the rangehood vents
out of the top of the chimney. Ductless installations require Charcoal Filters,
available from your dealer.
WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION,
DETERMINE WHICH VENTING METHOD WILL BE USED AND CAREFULLY
CALCULATE ALL MEASUREMENTS.
RANGEHOOD COMPONENTS
E
CALCULATE THE DUCTRUN LENGTH
The ductrun should not exceed 35 equivalent feet if ducted with the required
minimum of 6" round duct. Calculate the length of the ductwork by adding
the equivalent feet in FIGURE 2 for each piece of duct in the system. An
example is given in FIGURE 3.
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
12.0 feet
Wall Cap
FIGURE 2
For best results, use no more than three 90° elbows. Make sure that
there is a minimum of 24" of straight duct between elbows if more than
one is used. Do not install two elbows together. If you must elbow right
away, do it as far away from the hood's exhaust opening as possible.
I
H
F
G
D
A. CYLINDRA HOOD
A
B. MOTOR & SUPPORT
C. WALL SUPPORT SCREWS
D. BODY SCREWS
E. SCREW PLUG
F. PVC DUCTLESS PIPE
G. DAMPER
H. DUCTLESS GRILLE
I. DUCTLESS SCREWS
J. DUCTLESS RING
FIGURE 1
3.0 feet
9 Feet Straight Duct
5.0 feet
2 - 90˚ Elbows
Wall Cap
0.0 feet
Total System
FIGURE 3
J
C
B
9.0 feet
10.0 feet
0.0 feet
19.0 feet