ENGLISH
Continuity Testing
Continuity is indicated at less than 270kΩ of resistance.
GFCI Testing
Check the GFCI Receptacle user manual for more information.
Always contact a qualified electrician to resolve wiring problems.
Operate the Push Button on the GFCI Receptacle. If the GFCI circuit
does not trip, the receptacle is not operating properly.
To test the functionality of a Ground Fault Circuit Interrupter receptacle,
apply leads to the hot and ground terminals for 7 seconds.
• If the GFCI receptacle is wired properly, power to the circuit
will go out and the ET200 will stop indicating voltage.
• If the GFCI receptacle is wired improperly, power to the circuit
will remain and the ET200 will continue to indicate voltage.
To resolve an issue, contact a qualified electrician.
Battery Replacement
Batteries are not required for visual voltage indication.
1. Remove test leads from voltage source.
2. Unscrew battery cover and replace 3xAAA batteries.
WARRANTY
www.kleintools.com/warranty
CLEANING
Clean the instrument by using a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECYCLE
Caution:
This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
1-800-553-4676
customerservice@kleintools.com
www.kleintools.com
Instruction Manual
ENGLISH
• MODERN
SOLID-STATE
DESIGN
• INDICATES VOLTAGE
WITHOUT BATTERY
• LOW IMPEDENCE
• CONTINUITY FUNCTION WITH
LIGHT, VIBRATION AND SOUND
INDICATIORS
600V
139575T Rev. 12/13 B
139645 Rev. 12/13 B
ET200