elektro gmbh & co. Kg
454 fu-sPV 4reg
ec switching module, 4-channel, with sPV
installation and operating instructions
GB
structure & DescriPtiOn
I1 I1 O1
I2 I2
O2
Function
Mode
1
1
0
2
0
2
LRN/CLR
10A μ
9
3
9
3
8
4
8
4
Status LED
7
5
7
5
6
6
Status
EC Modular System
454 FU-SPV 4REG
Output LEDs
1
2
~
100-240 V AC
24 V DC
channel
50-60 Hz
0,3 A
–
3
4
on/off
on/off Button
4 x 10A/240V AC μ (I
max 4x10A / I
max 4x3A)
M
N
N
Aerial module
connection
10A μ
10A μ
24V
A
B
0V
I3 I3 O3
I4 I4
O4
L
N
The switching module is part of the Easyclick (EC) modular
system developed by PEHA. The system is based on radio
transmitters and receivers which operate at 868.3 MHz fre-
quency, to wirelessly control consumers.
When a transmitter sends a signal to the switching mod-
ule (radio receiver), a switching function is performed. The
function can be individually programmed for each radio
transmitter. Pressing "on/off" on the switching module also
enables operation.
The function switches the electrical consumers that are con-
nected to the outputs, such as bulbs, HV halogen lamps, or
inductive loads.
• Programmable function for each assigned radio transmitter
• Rotary switch for setting function and mode
• Modular sockets and plugs for data connection and
voltage supply to further modules.
• Secure reception of Enocean radio telegrams via external
Easyclick aerial module
• Max. 128 modules per system (including aerial module)
• Bidirectional functions (transmit/receive) integrated.
notes:
– Read through the operating instructions carefully
before putting the device into service.
– Radio transmitters (max. 64) must be assigned to the
outputs (channels) on the module prior to use!
– The operating instructions for the radio transmitters
must be observed!
Vorsicht! Kontamination
sAfety
Vorsicht, Gefahr durch
Vorsicht, Gefahr durch
Abquetschen
Abschneiden
cAutiOn! Danger of electrical shock!
the housing contains current-carrying components.
contact can lead to personal injury! All work on the
Vorsicht, Gefahr durch
mains network and the device may only be perfor-
Vorsicht, Gefahr durch
Vorsicht, Gefahr durch
elektrischen Strom
elektromagnetische
explosionsgefährliche
Strahlung
Stoffe
med by an authorised electrician.
• Disconnect power supply from the device.
• Secure the device against being powered on again.
• Check that the device is powered off.
Vorsicht, Gefahr durch
Vorsicht, Gefahr durch
Vorsicht, Gefahr durch
• Close the housing securely before applying power.
Laserstrahlung
Radioaktivität
Rutschen
This device is only intended to be used for its stated appli-
cation. Unauthorised conversions, modifications or changes
are not permissible! This device may not be used in conjunc-
Vorsichtig verschieben!
Während der
Wandbrände nicht von
tion with other devices whose operation could present a
- veraltet -
Schweißarbeiten,
oben löschen
Arbeitsstelle beobachten
hazard to people, animals or property.
the following must be observed:
• Prevailing statutes, standards and regulations.
• State-of-the-art technology at the time of installation.
Wandhydrant, mit Angabe
Wareneingang -
Wareneingang - Gesperrt
des Anschlusses
Freigegeben
• The device's operating instructions.
• operating instructions can only cite general stipulations.
These are to be viewed in the context of a specific system.
454 FU-SPV 4REG (Rev03-190408)
technicAL infOrMAtiOn
general data
operating voltage
100-240 V ~ / 50-60 Hz
(terminal N, L)
Standby
own consumption
operation = max. 100mA / 2,4W
Automatic circuit breaker
Fuse
(max. 16A)
Power supply
Nom. 24 V DC (SELV)
Modular System
via modular sockets
Output current
0,3A
Transmission frequency 868,3 MHz
Consumer output
4 potential-free relay outputs
(Terminal
)
(switching capacity max. 10A
O1-O4
Consumer voltage
External voltage supply
(Terminal
)
230-240V ~ / 50-60 Hz
I1-I4
Ambient temperature
-20 to +40 °C
Storage temperature
-40 to +85°C
Screw terminals
max. 2 x 1.5 mm²
Test specifications
EN 60669-2-1
Identification
KEMA KEUR ; CE
Protection level
IP20
Width = 72 mm (4TE)
Dimensions
Height = 55 mm
Load specifications per consumer output (230V ~ / 50hz)
Light bulbs (ohmic)
HV halogen lamps
Motor load
Uncompensated fluorescent tubes
rAnge
Radio signals are electromagnetic waves. The farther away
the transmitter is, the weaker is the field strength surround-
ing the receiver. As such, the range is limited. Different ma-
terials or interference sources in the direction of the signals
can further reduce the range. The range can be increased by
the use of Easyclick Repeaters (radio amplifiers).
Material
Wood, plaster, non-coated glass
Masonry, wood/plaster walls
Reinforced concrete
range
conditions
Under good conditions
> 30 m
(large, clear space without obstructions).
Through up to 5 plaster/drywall board
walls or 2 plasterboard/partition walls
> 20 m
(furniture and people in the room):
For transmitter and receiver with good ae-
rial positioning/layout.
Through up to 5 plaster/drywall board
walls or 2 plasterboard/partition walls
(furniture and people in the room):
> 10 m
For receivers installed in walls or corners
of rooms, receivers with internal aerial or
narrow corridors.
Through 1-2
Depending on ceiling/wall armouring and
Vorsicht, Gefahr durch
ceilings/ walls
type of aerial in the receiver.
Abstürzen
note: Go to www.peha.de for further information on "Range".
Vorsicht, Gefahr durch
feuergefährliche Stoffe
Vorsicht, Gefahr durch
Stolpern
Wandbrände von unten
nach oben löschen
Wärmeabzugseinrichtung
PLAnning AiD fOr cALcuLAting the necessAry POwer suPPLy
ec module, external device or accessory
= less than 1W
2000 W
1500 W
3 A
18 x 58 W
reduction
0 - 10%
5 - 35%
10 - 90%
current in
Σ current requirement
Quantity
mA
in mA
total:
(max. 300 mA)
gb - 1