GAS COOKTOP INSTALLATION INSTRUCTIONS
4. Adjust the "lOW" setting for regular
surface burner valves (Figure 10)
a. Push in and turn control to liTE until burner
ignites.
b. Quickly turn knob to lOWEST POSiTiON.
c. If burner goes out, reset control to OFF.
d. Remove the surface burner control knob.
e. Insert a thin-bladed screwdriver into the
hollow valve stem and engage the slotted
screw inside. Flame size can be increased
or decreased with the turn of the screw. Turn
counterclockwise to increase flame size. Turn
clockwise to decrease flame size. Adjust flame
until you can quickly turn knob from liTE to
lOWEST POSiTiON without extinguishing the
flame. Flame should be as small as possible
without going out.
Counterclockwise
Hollow
Valve
Stem
Regular
Burner
Valve
Figure 10
Note: Air mixture adjustment is not required on
surface burners.
Clockwise
A
B
Dual
Burner
Valve
5. Adjust the "lOW" setting of the dual burner
surface valve (Figure 10) (some models):
Note: On the dual valve the low setting of each
portion should be adjusted individually.
a. Push in and turn knob to liTE then continue
to turn until only the inner portion of the dual
burner stays on.
b. Quickly turn knob to lOWEST POSiTiON.
c. If burner goes out, reset control to OFF.
d. Remove the surface burner control knob.
e. The inner portion of the dual burner flame
size can be increased or decreased with the
turn of the screw B. Use screw A to adjust the
low flame size of the outer portion of the dual
burner. Turn the screw counterclockwise to
increase flame size. Turn the screw clockwise
to decrease flame size. Adjust flame until you
can quickly turn knob from HiGH to lOWEST
POSiTiON without extinguishing the flame.
Flame should be as small as possible without
going out.
Note: Air mixture adjustment is not required on
surface burners.
When All hookups are Complete
Make sure all controls are left in the OFF position.
Make sure the flow of combustion and ventilation
air to the cooktop is unobstructed.
model and Serial Number location
The serial plate is located on the underside of the
cooktop.
When ordering parts for or making inquires about
your range, always be sure to include the model
and serial numbers and a lot number or letter from
the serial plate of your cooktop.
Your serial plate also tells you the rating of the
burners, the type of fuel and the pressure the
cooktop was adjusted for when it left the factory.
Before You Call for Service
Read the Before You Call for Service Checklist
and operating instructions in your Use and Care
Guide. It may save you time and expense. The
list includes common occurrences that are not the
result of defective workmanship or materials in
this appliance.
Refer to the warranty in your Use and Care
Guide for our service phone number and address.
Please call or write if you have inquiries about
your product and/or need to order parts.
9