6) Advanced settings (PL)
» Installer parameters
» Press the buttons
» Scroll using the buttons
"set"
. Select the parameter to be modified (see table below) using the but-
tons
buttons
» Press "set"
Param Description
Room sensor calibration
Factory reset
Hysteresis ON (*)
Hysteresis OFF (**)
Display illumination duration
Flow max set point (***)
Flow min set point (***)
Climate curve (***)
Boiler CH set point (***)
Exit
(*) the request is activated if T. amb < Tset -HOn
(**) the request is deactivated if T.amb > Tset + HOf
(***) only with OpenTherm connection
to select the "Pl" menu, and then "set"
and press "set"
then press "set"
or "mode"
to return to the previous menu.
Step Unit Default
0.1
0.1
0.1
1
1
1
cod. 3541T131 - Rev. 02 - 06/2021
, until reaching the value "Ps 10" then press
. Modify the selected parameter using the
to confirm the change.
°C
Room temperature
---
NO
°C
0.4
°C
0.1
08
°C
85
°C
30
---
1.2
°C
85°C
to access.
Range
-7.0 + 7.0 °C
NO - YES
0.0 ÷ 2.0
0.0 ÷ 2.0
03 ÷ 15
45 ÷ 85°C
10 - HHCH
0.0, 0.2, 0.4, 0.6,
0.8, 1.0, 1.2, 1.5,
2.0, 2.5, 3.0
30 ÷ 85°C
55