Equipment fitted in valve locations 1 to 4 or 5 to 8
2 double−
solenoid valves
1
3
5
2
4
[J
6 7 6 7
DIP switch setting (see 3.8)
1: ON
2: OFF
3: ON
4: OFF
[J ... 3 Addresses of the solenoid coils for AS−Interface address
n/m
4 Addresses or LEDs of solenoid coil 14
5 Addresses or LEDs of solenoid coil 12
6 Valve plates with 2 valve solenoid coils, such as 2 single−
solenoid valves, 5/2−way double−solenoid valve or 5/3−way
valve (e.g. code J, N, C, H, G, D, I, E)
7 Blanking plate or separator plate (e.g. code L, S, T)
8 Valve plates with 1 valve solenoid coil (e.g. code M, F, A)
*)
or blanking plate or separator plate
24
4 single−
solenoid valves
5
[J
1
2
3
4
8 8 8 8
1: OFF
2: ON
3: OFF
4: ON
1 double−solenoid valve,
2 single−solenoid valves
1
5
2
3
4
[J
6 7 8 8
1: ON
2: OFF
3: OFF
4: ON
*)
Festo CPV..−GE−ASI−8E8A−Z M8 0306c English
3
5
[J
1
2
4
8 8 6 7
1: OFF
2: ON
3: ON
4: OFF
*)